9 R
EPAIR
9.3 O
PENING THE CASING
9.3

OPENING THE CASING

Removing the dust/splash
9.3.1
guard
At ALS 20X machines, which are equipped with the
IP65 option, the connection cover boxes [207A, B] must
be removed before opening the housing.
Prerequisites:
– The machine is de-energised.
Tools:
– Hexagon socket driver SW 2.5 and 3
Unscrew four screws [207A arrows].
Remove the cover box[207A] off carefully.
– By doing so, the power connector on the inside of
the cover box is removed.
If the cover box for interfaces [207B] is prevailing:
If prevailing: Pull the Ethernet connector off from the
cover box.
Unscrew four screws [207B arrows].
Remove the cover box [207B] carefully. While doing
so, unplug the interface cables from the machine.
A
[207] Housing with IP65 equipment (IT2).
A Cover box for power supply connection
B Interface cover box