Avery Dennison ALS 204 Service And Installation Manual page 136

Hide thumbs Also See for ALS 204:
Table of Contents

Advertisement

7
E
LECTRONICS
7.3 C
IRCUIT BOARDS
Installing the Applicator Interface
Requirements for the subsequent installation:
– ALS 20X or ALS 256
– Applicator Interface (Article no. A4455)
– Data cabel AI - CPU (Article no. A5001)
– Y supply cabel AI - CPU - Fan (Article no. A6805)
Tool:
– Hexagon socket driver 2,5 mm
Open the casing, see Ch. 9.3 Opening the casing
(page 186).
Remove two screws [137B] at the slot cover.
Remove slot cover.
Remove two screws [138A] at the board rack. Care-
fully pull out the board rack, until the connections at
the rear end of the CPU board are accessible.
Connect both cables to the CPU board and to the
Applicator Interface, see Ch. 7.1 Wiring Diagrams
(page 116).
Plug the Applicator Interface board onto the spread
sockets [139A]at the board rack.
Reinstall the board rack. While doing so, pay atten-
tion,
– that the noses at the rear end of the board rack fit
into the holes at the housing rear wall.
– not to wedge any cable between board rack and
housing.
Close the casing.
D
ESCRIPTION
136
B
A
[137] Slot cover (A) with mounting screws (B).
A
A
[138] Board rack with mounting screws (A) (LH version pictured).
A
[139] Plug the Applicator Interface onto the spread sockets (A)
on the board rack.
ALS
20X
256
B

Advertisement