3
I
NSTALLATION AND DEINSTALLATION
3.2 C
ONNECTING THE SENSORS

Alternative label sensor

3.2.2
Other suitable sensors can be used as an alternative to
the throughbeam photoelectric sensor.
– Permitted sensor types: PNP or NPN
– Default setting: PNP
Alternative label sensor and standard photo-
electric sensor may both be connected at the
same time. Selection of the active sensor is
done by calling the function
Label sens.
type. The setting is stored within the
product profile.
Connecting the sensor
Plug the sensor in to the connector shown [51A]
(ALS 256: [51B]).
Connection accessories
Connector (cable-Ø 4-6 mm)
Connector (cable-Ø 6-8 mm)
Connecting cable (coupling-plug)
Pin assignment
Pin
Assignment
1
+24 V
2
+24 V or ground or no
1)
connection
3
Ground
4
Sensor signal
1) chapter "Changing light/dark switching at the product sensor or the
alternativ label sensor" on page 47