Avery Dennison ALS 204 Service And Installation Manual page 148

Hide thumbs Also See for ALS 204:
Table of Contents

Advertisement

7
E
LECTRONICS
7.5 S
I
IGNAL
NTERFACE
PEP II Sensor
Start signal
Home position
Airstream support
Cylinder
(setable)
Vacuum
Touch down
C
Blow on
(setable)
Additional signals with optional Applicator Interface:
Offline
Cycle
D
Inhibit
[158] Pattern of control signals over time for PEP II Sensor
applicators.
A Duration is determined by label length and dispensing
speed. „Airstream Support" switching to low means the label
is dispensed.
B Duration t is determined by the backwards movement of the
applicator. The application cycle ends when the home
position signal is high again.
C Adjustable with "Blow on time".
D The output signal „Offline" follows the input signal „Inhibit".
E The start signal is ignored because of the active „Inhibit".
D
ESCRIPTION
A
B
t
E
148
ALS
20X
256