8
F
AULT DESCRIPTION
8.1 T
YPES OF STATUS MESSAGES
Status Status text
5001
No gap found
5002
Material end
5009
Start error
5019
Startsig. overrun
[196] List of error messages
Cause
– Material end, if no outer diameter
(OD) control is activated.
– The maximum limit for missing labels
was exceeded (
LABEL SETUP
bel tol.
).
– The machine is not correctly set for
MACHINE SETUP
the type of label (
bel sens. type
).
– Label length is not correctly set (
BEL SETUP
>
Label pitch
).
– Photoelectric label sensor is dirty.
– Photoelectric label sensor is incor-
rectly positioned.
– Photoelectric label sensor is not con-
nected correctly.
– Photoelectric label sensor is defec-
tive.
– Rotary encoder is not adjusted cor-
rectly.
– Material end (if the internal OD-con-
trol is activated).
– Refers to the standard start sensor
input (M12).
– The device received another start
signal while applying a label.
MACHINE SETUP >
– Prerequisite:
ror stop
is set to "On" .
– Too high start signal frequency
caused start signal buffer overflow.
– Possible causes: Distance between
product sensor and dispensing edge
is too high and/or to high product
170
Action to take
Check the points listed above and
correct if necessary.
Press the
>
Miss. la-
ror message.
>
La-
LA-
Insert new label roll.
Check the operation of the labeller;
increase distance between products
if required.
MACHINE SETUP >
Set
Start er-
"off".
Decrease distance between product
sensor and dispensing edge.
Decrease dispensing/conveyor
speed.
Increase product distance.
ALS
20X
256
key to confirm the er-
Start error stop
to

Advertisement

Table of Contents
loading

This manual is also suitable for:

Als 206Als 256

Table of Contents