[77] The appearance of those menu functions depends on the se-
lected applicator type (x = function appears).
Status outputs function:
– Determines the output signals at pin 7 and 8 at the
signal interface.
– Settings: [Deactivated, Enabled]
Deactivated: Assignment of applicator signals
(pin 7 = vacuum, pin 8 = blow on)
Enabled: Assignment of status signals (pin 7 =
dispense end, pin 8 = warning)
Apply mode function:
– Determines whether the application process begins
with application ("after start sig.") or dispensing ("af-
ter dispensing") of a label.
– Settings: ["After dispensing", "After start sig "]
"After dispensing": The start signal triggers both the
dispensing and the application of a label.
"After start sig.": The start signal triggers the
application of a label that has already been
dispensed. The next label is then dispensed
immediately after application.
Functions
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Dwell time function
SIGNAL INTERFACE >APPLIC.
– Appears only if
SIGNALS > Applicator type
„Reverse PEP"; BTS or „LA-TO Timed"
– Determines the length of time for which the applica-
tor is extended
– Is required for applicators that are not limited by a
touch-down signal
– Dedicated signal output: Pin 5 at the signal interface
– Adjustment range: [1...99999] ms; default: 200 ms
(LA-TO Timed: 500 ms)
Blow on time function:
SIGNAL INTERFACE >APPLIC.
– Appears only if
SIGNALS > Applicator type
„Reverse PEP", BTS, „O-ring applicat." or LA-BO
– Sets the duration for blowing on of each label
– Only appears when an applicator that requires blow-
ing on is used (e.g. "PEP Blow on")
– Dedicated signal output: Pin 8 at the signal interface
– Adjustment range: [0...99999] ms; default: 50 ms
(LA-BO: 60 ms)
Restart delay function:
– Determines the length of time after application for
which no start signals will be accepted.
– Adjustment range: [0...99999] ms; default: 0 ms
Position timeout function:
– Does not appear, if
SIGNALS > Applicator type
LA-BO
– Determines the length of time after which an appli-
cator position error is displayed as an error. A posi-
tion error is considered to have occurred if the
applicator has failed to reach one or both of its end
positions within the time set.
– Adjustment range: [500...99999] ms; default:
2000 ms
69
= PEP, „PEP Blow on",
= „PEP Blow on", ASA,
SIGNAL INTERFACE >APPLIC.
= ASA, „Direct Dispense" or
ALS
20X
256