Forced Bootloader Start - Avery Dennison ALS 204 Service And Installation Manual

Hide thumbs Also See for ALS 204:
Table of Contents

Advertisement

6
E
NHANCED
6.5 F
ORCED BOOTLOADER START
6.5

FORCED BOOTLOADER START

A forced bootloader start is required, if the dispenser
firmware hung up and the machine will not get ready for
operation even after a restart.
Switch the machine off.
Keep the buttons
neously switch on the machine.
The bootloader appears:
Boot Loader V x.x
115KB, 8N1
Avery Dennison
Dispenser-CPU32
x.x = Bootloader version
Press the
button.
The menu LOADER FUNCTIONS with the single
function „Clear Params" shows up:
LOADER FUNCTIONS
Clear params
Avery Dennison
Dispenser-CPU32
Press the
button.
Clear params
no
Avery Dennison
Dispenser-CPU32
Press the
button to change to „yes".
Press the
button.
All settings in the functions menu are deleted, inclu-
ding the setting which caused the firmware to crash.
Switch the machine off.
Switch the machine on while keeping the buttons
+
pressed, until the machine type is dis-
played.
F
UNCTIONS
+
pressed and sumulta-
After this display:
Code:
press the following buttons in succession:
,
,
,
Set the machine type under
Dispenser type
.
Switch the machine off and on again after waiting at
least 10 s in between.
111
, 3x
.
MACHINE SETUP >
ALS
20X
256