Avery Dennison ALS 204 Service And Installation Manual page 109

Hide thumbs Also See for ALS 204:
Table of Contents

Advertisement

6
E
NHANCED
6.4 I
NTERFACE COMMANDS
The #!PC command
Syntax:
#!PC<Function ID>/<Value>
Immediate command for setting of function values. In
comparison to the #PC command, only the functions
listed afterwards can be set this way. The settings take
effect immediately.
<Function ID>
<Value>
2005
n = 0 - Maxint
2065
n = 0 - 16
3213
n = 0 - 10000 ms
6000
f = 0.0 - MAX m/min
6001
f = 0.0 - MAX m/min
6002
f = 5.0 - 500.0 mm
6003
f = 0.0 - 999.9 mm
6004
f = 15.0 - 9999.9 mm Start offset
6010
n = 0 - 100 %
6016
n = 0 - Maxint
6017
f = 0.0 - 1999.9 mm
[110] Functions which are setable with the #!PC function.
1)
Maxint = 4294967296
The #!SP command
Syntax:
#!SP
– In dispensing mode, the following is displayed after
sending the command:
ONLINE
Gestoppt:
– Continuing the dispensing: press the
send #!SR.
F
UNCTIONS
Function
1)
Label counter
Loads product profile no. „n". A va-
lid product profile must be stored
under this number. After the com-
mand, a restart is executed.
Signal delay after dispense end
Dispensing speed
Slew speed
Material length
Label stop position
Adjustment label sensor
1)
Label amount
Product length
xxx
button or
Function in menu
MACHINE SETUP > Dispense counter
LABEL SETUP
SIGNAL INTERFACE >PLC SIGNALS>
Disp.end delay
LABEL SETUP > Dispense speed
LABEL SETUP > Slew speed
LABEL SETUP > Label pitch
LABEL SETUP > Lab. stop offset
LABEL SETUP > Start offset
MACHINE SETUP > Sensor Adjust
LABEL SETUP > Label stop quan.
LABEL SETUP > Product length
109
ALS
20X
256
>
Load prod.profil