4.1 F
UNCTION MENU
4.1 F
UNCTION MENU
Submenu >COM1 PORT
Baud rate function:
– Data transfer rate
– Settings: [300, 600, 1200, 2400, 4800, 9600, 19200,
38400, 115200] bit/s
No. of data bits function:
– Settings: [7, 8]
Parity function:
– The parity bit is used to check the data transfer. If
the check reveals an error, a message is displayed
accordingly. The setting must be the same for both
transmitter and receiver. The normal set-up is for
transfer without a parity bit.
– Settings: [Odd, Even, None, "Always zero"]
Odd parity. A parity bit is added in such a
Odd:
way that the total number of 1 bits is odd.
Even: Even parity. A parity bit is added in such a
way that the total number of 1 bits is even.
None: No check bit.
"Always zero": The check bit is always 0 (zero). For
transmission and reception without parity checking.
Stop bits function:
– Settings: [1, 2]
Data synch. function:
– Settings: [RTS/CTS, XON/XOFF, None]
RTS/CTS: Data synchronisation by hardware
XON/XOFF: Data synchronisation by software
None: Handshake lines are not monitored
Frame error function:
– Settings: [Display, Ignore]
Display: An error message is shown if frame errors
occur during serial transfer.
Ignore: Frame errors are ignored, no error message
is displayed.
Submenu >NETWORK PARAM.
General rules for entering addresses:
– To change to the next/previous alphanumer-
ic character:
Press the
– To confirm selection and move to the next
position:
Press the
Alternatively, inputting can be carried out via
the WEB Server function.
– See "Web server" on page 95.
IP Addressassign function:
– Settings: ["Fixed IP address", DHCP]
"Fixed IP address": This setting activates the "Net
mask" and "Gateway address" parameters (see
below).
DHCP: The IP address is assigned automatically.
The IP address assigned is shown briefly in the
display while the system starts up.
IP address function:
Enter IP Address in the form xxx.xxx.xxx.xxx
– Possible range for each xxx value: [0...255]
Net mask function:
Enter address of the network mask in the form
xxx.xxx.xxx.xxx
– Possible range for each xxx value: [0...255]
– default: Depends on the IP address set (it is recom-
mended that you adopt the default value)
Gateway address function:
Enter address of the gateway in the form
xxx.xxx.xxx.xxx
– Possible range for each xxx value: [0...255]
– 000.000.000.000 = no gateway address used
Port address function:
– Adjustment range: [1024...65535]; default: 9100
Ethernet speed function:
– Settings: [Automatic, "10M half duplex", "10M full
duplex", "100M half duplex", "100M full duplex"]
Automatic: The transfer rate is set automatically.
"10M Half duplex": Transfer rate = 10 MBit/s with
half duplex operation.
66
ALS
20X