Avery Dennison ALS 204 Service And Installation Manual page 63

Hide thumbs Also See for ALS 204:
Table of Contents

Advertisement

4.1 F
UNCTION MENU
4.1 F
UNCTION MENU
None: No tandem operation (together with
Operation
= „Disabled").
Serial Com1: Tandem synchronisation over Com1
(INTERFACE PARA >EASYPLUGINTERPR > Interface
function must not be set to „Serial Com1" or to
„Automatic").
UDP Tandem Port: Tandem synchronisation over
Ethernet.
Slave IP address function:
– Input of the IP address of the slave if tandem syn-
chronisation over Ethernet is selected.
MACHINE SETUP > Tandem Operation
– Appears only if
„Master" or „Flipflop master" and if
Tandem synchron.
= „UDP Tandem Port".
Type in the IP address according to the scheme
xxx.xxx.xxx.xxx.
– Setting range for each xxx-value: [0...255];
default: 0
Tandem Distance function:
– Distance between the dispensing edges of master
machine and slave machine
– Adjustment range: [100...1500] mm; default: 500
Label sens. type function:
– Type of photoelectric label sensor
– Settings: [Optical, Capacitiv]
Optical: Throughbeam photoelectric sensor for
transparent backing material
Capacitiv: Capacitive or other alternative label
sensor
Labelsen. InType function:
– Input type of the alternative label sensor (not valid
for the standard (Wenglor) photoelectric label sen-
sor)
– Settings: [NPN, PNP]
Startsen. In.Type function:
– Product sensor input type
– Settings: [NPN, PNP]
Start disp. mode function
– Defines either the rising or falling side of the start
signal peak as the point when dispensing is trig-
gered.
– Settings: [„Pulse falling", "Level low active", "Pulse
rising", "Level high active", "Pulse fall/rise"]
Tandem
"Pulse falling": Dispensing a label is triggered by a
change from high to low at the "sensor signal" input.
"Level low active": Setting is only visible in
production mode. Labels are dispensed for as long
as the signal at the "sensor signal" input remains at
the value low.
"Pulse rising": Dispensing a label is triggered by a
change from low to high at the "sensor signal" input.
"Level high active": Setting is only visible in
production mode. Labels are dispensed for as long
as the signal at the "sensor signal" input remains at
=
the value high.
MACHINE SETUP >
"Pulse fall/ris": Dispensing a label is triggered both
by a change from low to high and by a change from
high to low at the "sensor signal" input.
Start error stop function:
– Refers to the standard procuct start input (M12 con-
nector), see chap. "Photoelectric product sensor" on
page 48.
– Determines how the machine reacts to a product
start error. A product start error occurs whenever a
further start signal is received while a label is still be-
ing dispensed (given that
length
When a start error occurs, the machine shows a
warning or an error message, depending on the
setting.
– Settings: [On, Off, „Off label queued"]
On: A start error is followed by the error message:
The machine stops.
Off: A start error is followed by the warning:
The machine continues labelling. The warning can
be set back by Easy-Plug command #!CLRW.
„Off label queued": Too early start signals are
queued. They are processed, as soon as the
machine is idle again.
63
LABEL SETUP > Product
= 0).
Status num:
5009
Start error
ONLINE
Productstartwarn
ALS
20X
256