4.1 F
UNCTION MENU
4.1 F
UNCTION MENU
On inhibit enter function:
– „On entering inhibit" means „after the inhibit signal
has been applied"
„Inhibit" is an input signal, which supresses in-
coming start signals, what means, that start sig-
nals are being ignored as long as „Inhibit" is ac-
tive. Nevertheless, incoming start signals are
being registered . Registered products are products,
which find themselves between start sensor and dis-
pensing edge.
– The function determines, how products are handled,
which already had passed the start sensor, as the
inhibit signal applied. The start signals triggered by
the products are registered in a queue.
– For details about the effect of the function, read
chapter "Impact of the inhibit signal" on page 14
– Settings: [„Do regist starts", „Del regist strts"]
„Do registered starts": The queue is not touched.
Registered products are labelled.
„Delete registered starts": The queue is deleted.
Any started labelling cycle is finished.
On inhibit leave function:
– „On leaving inhibit" means „after the inhibit signal
stopped"
– The function determines, how products are handled,
which already had passed the start sensor, as the
inhibit signal stopped. The start signals triggered by
the products are registered in a queue.
– Settings: [„Do regist starts", „Del regist strts"]
„Do registered starts": Registered products are
being labelled as soon as the first product reaches
the dispensing edge.
„Delete registered starts": The queue is deleted.
Incoming start signals are registered.
Materialend err function:
– Refers to the internal OD control.
– Settings: [Disabled, „Mat.diam < x mm"]
– Setting range for x = [40,0...500,0]
– Default setting: x = 60
Deactivating the function:
Set x < 40.
Re-activating the function:
Press the
key.
Defines the diameter threshold for the material roll.
If the (calculated) material roll diameter is below the
threshold value, the following status message
appears:
Status num:
Material end unw
An additional material end error is caused, if no
unwinder rotation is detected during at least 600 mm
of material feeding:
Status num:
Material end unw
Materialend warn function:
– Refers to the internal OD control.
– Settings: [Disabled, „Mat.diam < x mm"]
– Setting range for x = [40,0...500,0]
– Default setting: x = 80
Deactivating the function:
Set x < 40.
Re-activating the function:
Press the
key.
Defines the diameter threshold for the material roll.
If the (calculated) material roll diameter is below the
threshold value, the following warning appears:
ONLINE
Material low
Rewinder full function
Defines the maximum permissible diameter of the
wound backing paper on the backing paper
rewinder. If the diameter is exceeded, the following
status message appears:
Status num:
Rewinder full
– Setting range: [50...500] mm; Default setting:
202 mm
Ext. OD sensor function:
– Refers to the external OD light barrier (option).
– Settings: [Off, Warning, Error]
Off: OD sensor is disabled.
Warning: OD sensor is enabled. If the outer roll
diameter is less than the critical value, the signal
output „Warning" is activated.