Avery Dennison ALS 204 Service And Installation Manual page 45

Hide thumbs Also See for ALS 204:
Table of Contents

Advertisement

3
I
NSTALLATION AND DEINSTALLATION
3.2 C
ONNECTING THE SENSORS
Connection Diagram
Sensor
connector
[52] Connection diagram alternativ label sensor. Jumper descrip-
tion see ch. 3.2.3 (p. 47)
Example: capacitive label sensor
– Application: transparent Labels
– Order numbers: A7775 (di-soric sensor including
mounting material and connection cable);
A101452 (sensor only)
– See
www.di-soric.de
Installation:
Tools:
– Hexagon socket drivers 4/6 mm
Turn out screw [53C] and remove the dispensing
edge [53E].
Remove the screws from the bottom ends of the hol-
ding rods. Take off the dispensing edge
holder [53D].
Push the sensor holder [53A] onto the holding rods
and fix it with the thumb screw [53B].
Reinstall dispensing edge holder and dispensing
edge.
Connect the cable.
+24V
+24V
1
2,2k
1k
1,5k
Signal
4
Input
1k
2,2k
GND
3
2
Jumper
(default: open)
NPN-Configuration
NPN-Signal
PNP-Signal
PNP-Configuration
[53] L-shape dispensing edge with capacitive label sensor
installed (Leuze type at LH machine).