8
F
AULT DESCRIPTION
8.1 T
YPES OF STATUS MESSAGES
Status Status text
9020
Param ID incorrect An invalid parameter ID was used.
9022
No network link
9025
24V voltage miss
9100
Invalid format
9101
Invalid header
9102
Inv. board rev.
9103
Invalid firmware
9104
Inv. data size
9107
Flash overflow
9108
Flash ovf. diag.
9109
Flash ovf. params
9110
Flash write err.
9116
Ser. disp. missing
9117
Device unknown
[196] List of error messages
Cause
This status message can only appear
when Ethernet address assignment is
INTERFACE PARA
set to DHCP (
WORK PARAM.
>
IP Addressassign
cause is almost invariably an incorrectly
plugged-in network connector.
The 24 V output voltage was not detect-
ed during system start.
Format error in download data, e. g.:
– invalid data format
– invalid checksum
– invalid address
– invalid record type
Format error in the dowload data
header.
Download data is incompatible to the
current board revision.
Download data is incompatible to the
current board.
The size of download data exceeds the
predefined size, which is set in the
header.
Onboard flash memory is full.
The available flash area doesn´t provide
enough space for diagnosis information.
The available flash area doesn´t provide
enough space to store the activ system
parameters.
The program flash cannot be accessed
for writing.
No (serial) operation panel found for
update.
Missing device information in the header
of the download data.
177
Action to take
Correct parameter ID.
Check whether the network connec-
tor is plugged in correctly, correct if
>NET-
necessary.
). The
Switch machine off and on again af-
ter 30 s. If the message continues to
appear, check power supply.
Check and modify download data.
Restart machine.
Check and modify header of down-
load data.
Restart machine.
Check and modify download data.
Restart machine.
Check and modify download data.
Restart machine.
Check and modify download data.
Restart machine.
Restart machine.
Delete flash data blocks.
Reduce max. size of diagnosis infor-
mation.
Functions are set to factory settings
after restart.
Reset machine.
Check machine, if an operation panel
is connected.
Download continues after the error mes-
sage.
Check and modify download data.
Restart machine.
ALS
20X
256

Advertisement

Table of Contents
loading

This manual is also suitable for:

Als 206Als 256

Table of Contents