8
F
AULT DESCRIPTION
8.1 T
YPES OF STATUS MESSAGES
Status Status text
5145
Rewinder full
5147
Tandemsynch. Init
5151
Applic. interf.
5152
Winding direct.
5200
Home position
5201
Touch Down
5203
Touch down sens. The touch down sensor(s) are/were trig-
[196] List of error messages
Cause
The maximum permitted diameter
(205 mm) for the rewinder roll has been
reached.
This message can only appear
during tandem operation.
– Communication between the master
and slave machines is not function-
ing.
Applicator interface is missing or not
connected.
– The backing paper end is not correct-
ly attached to the rewinder mandrel.
– Wrong machine type selected (
CHINE SETUP > Dispenser type
This message may appear when
operating the applicator. The ap-
plicator did not reach its home
position (upper end position)
within the intended time-frame.
– Applicator operation set, but no appli-
cator available.
– The applicator is stuck
– Compressed air applicator: Com-
pressed air supply interrupted or
switched off
– Cable not correctly connected.
The applicator lower end position
(Touch Down) was not reached in time.
gered before the application process
was started.
173
Action to take
Remove the rewound backing paper
This error can only occur if the
end of a new label roll was glued
on to backing paper that had al-
ready been wound onto the re-
winder.
Press the
ror message.
Check tandem interface cable.
– Is it a) in place and b) correctly con-
nected?
Check the settings on both machi-
nes.
– See "Setting up tandem operation"
on page 88.
Connect and/or install applicator in-
terface.
Attach the backing paper web to the
rewinding mandrel as described in
the user manual.
MA-
Setting „RH" at a LH machine or vice
)
versa.
Set
SIGNAL INTERFACE
to „PLC interface".
Remove any obstructions
Check compressed air connection
and reconnect correctly if necessary
Check cable and connect correctly if
necessary.
Check the cable and compressed air
connection; connect correctly if ne-
cessary.
ALS
20X
256
key to confirm the er-
>
Interface mode