9 R
EPAIR
9.4 U
NWIND UNIT
(ALS 20X) Install and adjust the eccentric
disc [246A]: Turn pin [246C] to approx. 20° from the
vertical.
(ALS 256) Install the disc.
Screw in the screw [246B] with Loctite 243 thread-
lock.
(ALS 20X) Before the threadlock hardens:
Slide the rubber disc and toroidal
transformer [247A] into place. There must be suffici-
ent distance between the toroidal transformer and
all other components around it. Pay particular atten-
tion to the distance from the power supply unit ca-
sing [247B].
(ALS 20X) Slide on second rubber disc and steel disc.
Screw toroidal transformer into place with nut [248A]
(ALS 20X) Connect the plug connections [248B, D].
Fit cable into guides [248C] and secure with cable
fasteners.
Install unwind spool and adjust axial play of unwind
spool on shaft - see Ch. 9.4.1 Expanding mandrel.
C
[246] Installing eccentric disc
B
[247] Installing the toroidal transformer
A
B
[248] Connecting the toroidal transformer
200
ALS
20X
256
A
B
A
C
D