8
F
AULT DESCRIPTION
8.1 T
YPES OF STATUS MESSAGES
Status Status text
5204
Appl. Starterror
5205
Applicator gen.
5206
Applicator resp.
5207
Appl. driver x
5208
(x=[1...4])
5209
5210
5212
Vx.x for AI rec
5250
PLC Out overload
5251
PLC 24V missing
5252
PLC out disabled
5253
24V switched off
[196] List of error messages
Cause
– Refers to the start input at the option-
al applicator interface.
– The device received another start
signal while applying a label.
– Prerequisite:
MACHINE SETUP > Start er-
ror stop
is set to "On" .
General software error
A time limit was exceeded while commu-
nicating with the applicator interface
(AI).
Short circuit or over-temperature at pow-
er output x of the applicator interface
(AI).
Wrong firmware for applicator interface
(AI) installed.
At least one PLC output signal is over-
loaded. Possible causes:
– Load to big
– Wrong wiring
– CPU board defective
24 V supply for PLC is missing. Possible
causes:
– 24 V cabling between power supply
and CPU is not available or defective
– Power supply is defective
– CPU is defective
PLC outputs are disabled. Possible cau-
ses:
– Watchdog timer expired
– Firmware error
– CPU board defective
24 V output of the power supply is swit-
ched off. Possible causes:
– General firmware error
– CPU board defective
174
Action to take
Check the operation of the labeller;
increase distance between products
if required.
Set "Start error stop" function to "off".
Switch the machine off, wait 30 se-
conds and switch it back on.
– See "General software errors" on
page 168.
Switch the machine off, then back on
again after half a minute.
If the error continues to occur after
switching on and off several times,
please contact our technical support.
Check connections.
Install AI firmware version x.x.
Reduce load.
Correct wiring.
Replace CPU board.
Check voltage cable; replace if ne-
cessary.
Replace power supply.
Replace CPU board.
Switch the machine off, wait 30 se-
conds and switch it back on.
– See "General software errors" on
page 168.
Replace CPU board.
Switch the machine off, wait 30 se-
conds and switch it back on.
– See "General software errors" on
page 168.
Replace CPU board.