6
E
NHANCED
6.1 A
CCESS VIA A
Applications
The web server makes it possible
– to set or read the values of functions from the func-
tion menu via a web browser
– to control the operator panel of the labeller via a web
browser.
The web server is not multi-session compatible,
i.e. only one user can be logged in at any time.
The web server is a setup utility, not an opera-
tional one. The web server should not be heav-
ily used during a high performance application
of the dispenser.
Prerequisites
– Labeller is connected to network
– A valid IP address is assigned to the dispenser (by
the network administrator or by a DHCP server)
INTERFACE PARA >NETWORK PARAM. > WEB server
must be set to "Enabled".
Starting the web server
Note down the IP address of the labeller
INTERFACE PARA >NETWORK
– This is shown under
PARAM. > IP address
Start internet browser.
Enter the following in the address bar:
http://[IP address without initial zeroes]
– Example: IP address = 144.093.029.031
Enter: http://144.93.29.31
Logging in to the web server
Click on the "Login" link [95B]
Enter user name and password [95F, G]
– Preset in both cases: admin
Click on the "Login" button [95H]
F
UNCTIONS
W
/FTP
EB
SERVER
91