Avery Dennison ALS 204 Service And Installation Manual page 153

Hide thumbs Also See for ALS 204:
Table of Contents

Advertisement

7
E
LECTRONICS
7.5 S
I
IGNAL
NTERFACE
Signal response „Dispense End"
The signal „Dispense End" can be controlled by the
SIGNAL INTERFACE >PLC SIGNALS
functions in the
menu.
A Duration of the dispensing operation [165A]
B Period setable via
SIGNAL INTERFACE >PLC SIGNALS >
Disp.end delay
[165B]
SIGNAL INTERFACE >PLC SIGNALS >
C Period setable via
End pulse width
[165C]
D Signal modes; setable via
SIGNALS > End dispense mod
– Modes high/low active : The signal is activated with
the start of dispensing. The duration is the sum of
the three periods A+B+C.
– Modes high/low pulse : The signal is activated after
dispensing ended and after period B and it lasts
period C [165C].
D
ESCRIPTION
sub-
SIGNAL INTERFACE >PLC
[165D]
153
dispense
high active
low active
high pulse
low pulse
A
[165] Signal response of „Dispense End".
ALS
20X
256
D
B C