6
E
NHANCED
6.4 I
NTERFACE COMMANDS
A
#!A1
#G Machine Setup for ALS 204 RH
B
#G Serial Number : A637105450041
#G MAC Address
#G-------------------------------------------------------------
#G LABEL SETUP
#G-------------------------------------------------------------
C
#PC6000/10.0
#PC6001/10.0
#PC6002/100.0
#G-------------------------------------------------------------------------
#G MACHINE SETUP
#G-------------------------------------------------------------------------
#PC5050/1
F
[107] Selection of function settings output after the #!PG-30 com-
mand is given
A Command to activate the interface
B Machine data, output in accordance with #!PG-4
C #PC<Function ID>/<Value> for the "Dispense Speed" func-
tion
D Plain text comment, output in accordance with #!PG-4
E Function type and permitted value range, output in accord-
ance with #!PG-8
F Machine-specific setting; in this case not commented out,
since #!PG-1 was used to insert a "*" at the start of the line
Function type Displayed in form
Integer
<i: 0 - 2147483647 (1)>
Float
<f: 5.0 - 600.0 (0.1)>
String
<s: 32>
Discrete
<d>
[108] Overview of function types
F
UNCTIONS
Version: V1.01
: 000a.44.04.00.1d
#G Dispense speed: 10.0 m/min
#G <f: 0.0 - 40.0 (0.1)>
#G Slew speed: 10.0 m/min
#G <f: 0.0 - 40.0 (0.1)>
#G Label pitch: 100.0 mm
#G <f: 5.0 - 600.0 (0.1)>
#G *Dispenser type : ALS 204 RH
#G <d>
#G 0 = ALS 204 LH
#G 1 = ALS 204 RH
#G 2 = ALS 206 LH
#G 3 = ALS 206 RH
Meaning
0 = minimum value
2147483647 = max. value
1 = Increment
5.0 = min. value
600.0 = max. value
0.1 = Increment
32 = max. string length
0 = Disabled
1 = Enabled
Example
MACHINE SETUP > Dispense counter
LABEL SETUP > Label pitch
INTERFACE PARA >NETWORK PARAM. >
DHCP host name
LABEL SETUP > Stop count. mode
107
ALS
20X
256
D
E

Advertisement

Table of Contents
loading

This manual is also suitable for:

Als 206Als 256