Start-Up And Shutdown; Turning On The Unit; Starting Label Dispensing; Dispensing With A Product Sensor - Avery Dennison ALS 204 Operating Instructions Manual

Label dispenser
Hide thumbs Also See for ALS 204:
Table of Contents

Advertisement

C
ONTENTS
4.1 S
-
TART
UP AND SHUTDOWN
4
O
P E RA TIO N
4.1

START-UP AND SHUTDOWN

Turning on the unit

4.1.1
Set the main switch [44A] of the unit to 'I' (On).
– The following messages are displayed during the
start process:
ALS204 RH:
V 1.00
(machine type and firmware version)
Memory:
16 MB
Flashcard
48 MB
(the machine's RAM, as well as the CF card's
memory, if a card is inserted)
ONLINE
Label
– Once switched on, the ALS 20x is in dispensing
mode; in other words, triggering the product sensor
will cause a label to be dispensed.
– You can find more information on the dispensing
mode in the section "Spendebetrieb" on page 18.

Starting label dispensing

4.1.2

Dispensing with a product sensor

Once switched on, the ALS 20x is in dispensing mode;
this means that triggering the product sensor will cause
a label to be dispensed.
Prerequisites:
– The label length must be specified.
– The product sensor must be connected.
– The sensors must be configured correctly
(PNP/NPN).

Dispensing without a product sensor

It is also possible to trigger the dispensing process
without a product sensor:
– The machine is in dispensing mode:
Press the
button.
– The machine is in configuration mode:
Press the
button briefly (less than two
seconds).
0
[44] Main switch (A) of the ALS 20x
39
ALS
20x
256
GB
A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: