Structure Of Tsm Service Program - B. Braun Dialog+ Service Manual

Sw 9.xx
Table of Contents

Advertisement

+
Dialog
SW 9.xx
4.3

Structure of TSM Service Program

T S M S e r v i c e P r o g r a m
Technical Support and Maintenance (SW 9.xx)
File
Operations
Hard Disk
Read/Write
Save Calibration Data
Download Calibration Data
Fig. : TSM Service Program
BA-TE-DE08C M.KAY
Dialog+ SW9xx_SM_Chapter 4-1-1_1-2010.doc/pdf <110301> yymmdd
4 . T S M S e r v i c e P r o g r a m
Treatment
Manual Test and
Support
System
TL Manual Test and
Configuration
Dialysate Side Parameters
Buttons, Lamps and Sounds
Blood Side Parameters
Monitor Test
Min-Max Parameters
Brightness
Arterial Bolus Parameters
Card Reader and Card Check
Single Needle
USB Port Properties
Heparin Parameters
Rinsing Parameters
File System Check
UF Parameters
HDF/HF Online Parameters
DBI Test
Disinfection Parameters
Kt/V-UV Sensor Test
Filter Parameters
DSI Test
Dialyser Filter Parameters Kt/V
Kt/V-UV Parameters
Timings
Langauge Selection
ABPM Parameters
bioLogic RR GL Parameters
Summer Time Setting
Miscellaneous Parameters
Test 1.1 Staff Call/Alarms/Power Off
DBI Parameters
Test 1.2 Blood Pump Arterial
DCI Parameters
Test 1.3 Blood Pump Venous
Preventive Service
Test 1.4 Heparin Pump
Test 1.5 Tubing Clamps
Trends and
Test 1.6 Pressure Sensors (Blood Side)
Test 1.7 Safety Air Detector, Red Sensor
Trend Groups
Test 1.8 Coupling Detectors
Test 1.9 Water Intake, Upline Tank and
Test 1.10 Degassing and Heating
Test 1.11 Dialysis Temperature
Test 1.12 Concentrate Pumps and
Test 1.13 Balance Chamber Valves
Test 1.14 By-Pass and Disinfection Valves
Test 1.15 Flow Pump FPA, Balance Chamber
Test 1.16 Pressure Water Part
Test 1.17 UF Pump
Test 1.18 Blood Leak Detector
Test 1.19 Leak Test
Test 1.20 Water Part (Overview)
Test 1.21 Emptying
{Test 1.22 HDF}
Low Level Manual
Calibration 2.1 Pressure Sensors (Blood Side)
{Calibration 2.2 Heparin Pump}
Calibration 2.3 Pressure Sensors (Water Side)
Calibration 2.4 Degassing Temperature
Calibration 2.5 Dialysis Temperature
Calibration 2.6 Conductivity
Calibration 2.7 Blood Leak Detector
Calibration 2.8 Flow of BICP, KP and UF Pump
Calibration 2.9 Safety Air Detector SAD
Calibration 2.10 BICLF Ratio and ENDLF Ratio
{Calibration 2.11 Load Cell}
Calibration 2.12 PV Alarm Window, PA Low Limit
Calibration 2.13 Flow of BPA and BPV Pump
{Calibration 2.14 Substitution Pump}
Calibration 2.15 HDF Online Substitution Pump OSP
Calibration 2.16 Level Regulation Pump LRP
Calibration
Calibration
Touch Screen Calibration
Supervisor Window Test
ABPM Maintenance
Low Level
Manual Test
Flow Pump FPE
Conductivity
Sensors
and Air Separator
Test 1.23 BIC Cartridge Valves and
Coupling Detectors
Test 1.24 HDF Online
Test 1.25 HDF Online Valves and Coupling
Detectors
Test 1.26 Option Battery
Test 1.27 DFS Pressure Test of Therapy
Test 1.28 Front Panel Board FPB (LLS)
Test 1.29 Patient Leakage Current
Test 1.30 SMPS-MC Self Test
Test 1.31 Level Regulation
Calibration
Calibration 2.8.1 Stroke Value of BICP, KP and UFP
Calibration 2.8.2 Position Setting for BICP, KP and UFP
Calibration 2.13.1 Tube Constants of BPA and BPV
Calibration 2.13.2 Pump Head Selection
1 / 2 0 1 0
Production
Report
Operation Mode
Machine
Delivery Data
Version Number
Dialog
Option Icons
ABPM
bioLogic RR
Card Reader
DCI
Kt/V
Kt/V-UV (Crit-Line)
HCT (Adimea)
Low Level Options
Double Pump
Holder for BIC Cartridge
DF Filter
HDF Online
Battery
Nexadia-BSL (DBI)
WAN-BSL (DBI)
{} : not applicable
B. Braun Avitum AG
4 - 8
Service
Reports
Report