Configure The Device To Use A User-Defined Static Location - Digi Connect IT 16 User Manual

Hide thumbs Also See for Connect IT 16:
Table of Contents

Advertisement

Services
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. Enable or disable the USB module:
a. Use the show command to determine the index number of the USB location source:
(config)> show service location source
0
1
(config)>
b. Use the index number to enable or disable the module:
n
n
4. Alternatively, you can use the index number to delete the USB location source:
(config)> del service location 0
(config)>
5. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
6. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.

Configure the device to use a user-defined static location

You can configured your Connect IT 16/48 device to use a user-defined static location.
  WebUI
Digi Connect IT® 16/48 User Guide
enable true
no label
type usb
enable true
no label
type gnss
To enable the module:
(config)> service location source 0 enable true
(config)>
To disable the module:
(config)> service location source 0 enable false
(config)>
Location information
371

Advertisement

Table of Contents
loading

This manual is also suitable for:

Connect it 48

Table of Contents