Configure The Web Administration Service - Digi Connect IT 16 User Manual

Hide thumbs Also See for Connect IT 16:
Table of Contents

Advertisement

Services
  Command line
1. Log into the Connect IT 16/48 command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. Add the External zone to the SSH service:
(config)> add service ssh acl zone end external
(config)>
4. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
5. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.

Configure the web administration service

The web administration service allows you to monitor and configure the Connect IT 16/48 device by
using the WebUI, a browser-based interface.
By default, the web administration service is enabled and uses the standard HTTPS port, 443. The
default access control for the service uses the Internal firewall zone, which means that only devices
connected to the Connect IT 16/48's LAN can access the WebUI. If this configuration is sufficient for
your needs, no further configuration is required. See
SSH
for information about configuring the web administration service to allow access from remote
devices.
Required configuration items
The web administration service is enabled by default.
n
Configure access control for the service.
n
Additional configuration items
Port to use for web administration service communication.
n
Multicast DNS (mDNS) support.
n
An SSL certificate to use for communications with the service.
n
Support for legacy encryption protocols.
n
See
Set the idle timeout for Connect IT 16/48 users
timeout for the web administration services.
Digi Connect IT® 16/48 User Guide
Configure the web administration service
Allow remote access for web administration and
for information about setting the inactivity
332

Advertisement

Table of Contents
loading

This manual is also suitable for:

Connect it 48

Table of Contents