11: SD M
C
EMORY
ARD
SD Memory Card Folder Structure and Files
Folder Structure
When downloading or uploading data using the FC6A Series MICROSmart or WindLDR, the following files and folders are accessible.
SD Memory Card
FCDATA01
(Fixed)
11-4
Arbitrary: File names and folder names that can be specified by the function area settings and
instruction parameters.
Fixed: File names and folder names that are fixed by the system.
The configuration file that defines upload and download actions when the FC6A Series
autoexec.ini
MICROSmart power is turned on and when special internal relays are used. This file is created
(Fixed)
by using WindLDR, but it can also be created and edited using a text editor.
mqtt_basic_settings.ini
(Fixed)
DATALOG
The folder used by the DLOG instruction.
(Fixed)
Log files are saved here.
RESULT
The folder name is specified by S1 in the DLOG instruction. The desired folder name up to 8
(Arbitrary)
single-byte alphanumeric characters can be set.
Log file
(CSV format)
PROGRAM
The folder used for downloading and uploading the user program.
(Fixed)
ZLD files are saved here.
One file that contains the user program, program comments, and the system software
fc6a01.zld
data for the CPU module.
(Arbitrary)
This file is created with WindLDR and by uploading data to the SD memory card.
RECIPE
The folder used by the recipe function.
Recipe files are saved here.
(Fixed)
RCP0001.csv
(Arbitrary)
FC6A S
MICROS
ERIES
The configuration file that defines basic settings for performing MQTT
communication. This file is created using WindLDR, but it can also be edited
using a text editor such as Notepad.
The CSV log file that is created when the DLOG instruction is executed.
For the Plus CPU module, a folder is created and given the date
(YYYYMMDD) as its name and then files are saved in that folder.
For details, see Chapter 25 "DLOG (Data Log)" in the "FC6A Series
MICROSmart Ladder Programming Manual".
The file where recipe values have been saved. The desired file name up to 7 single-
byte alphanumeric characters can be set. The default with the automatic setting is a
CSV file with the name RCP**** (where **** is 0001 to 9999).
(Example: RCP0001.csv)