Special Internal Relay - IDEC MICROSmart FC6A Series User Manual

Windldr
Hide thumbs Also See for MICROSmart FC6A Series:
Table of Contents

Advertisement

6: D
EVICES

Special Internal Relay

Special Internal Relay Device Addresses
Do not write to data in the area marked as reserved in the special internal relays list. Otherwise the system may not operate
Warning
correctly.
Note: R/W is an abbreviation for read/write.
The notation for the R/W field is as follows.
R/W: The device can be both read from and written to
R: Read-only
W: Write-only
Device
Address
M8000
Start Control
M8001
1-s Clock Reset
M8002
All Outputs OFF
M8003
Carry (Cy) or Borrow (Bw)
M8004
User Program Execution Error
M8005
Communication Error
M8006
Communication Prohibited Flag (When Data Link Master)
Initialization Flag (When Data Link Master)/Stop Communication Flag (When
M8007
Data Link Slave)
M8010
Status LED Operation
M8011
— Reserved —
M8012
M8013
Calendar/Clock Data Write/Adjust Error Flag
M8014
Calendar/Clock Data Read Error Flag
M8015
— Reserved —
M8016
Calendar Data Write Flag
M8017
Clock Data Write Flag
M8020
Calendar/Clock Data Write Flag
M8021
Clock Data Adjust Flag
M8022
User Communication Receive Instruction Cancel Flag (Port 1)
M8023
User Communication Receive Instruction Cancel Flag (Port 2)
M8024
BMOV/WSFT Executing Flag
M8025
Maintain Outputs While Stopped
M8026
User Communication Receive Instruction Cancel Flag (Port 3)
M8027
M8030
High-speed Counter (Group 1/I0)
M8031
M8032
M8033
User Communication Receive Instruction Cancel Flag (Port 4)
M8034
M8035
High-speed Counter (Group 3/I3)
M8036
M8037
— Reserved —
M8040
M8041
High-speed Counter (Group 4/I4)
M8042
M8043
M8044
High-speed Counter (Group 5/I6)
M8045
M8046
M8047
— Reserved —
M8050
6-4
Description
Count Direction Flag
Comparison Output Reset
Gate Input
Reset Input
Comparison Output Reset
Gate Input
Reset Input
Comparison Output Reset
Gate Input
Reset Input
Count Direction Flag
Comparison Output Reset
Gate Input
Reset Input
FC6A S
MICROS
U
ERIES
MART
Stopped
Maintained
Maintained
Maintained
Operating
Operating
Operating
Operating
Operating
Operating
Operating
Maintained
Maintained
Maintained
Maintained
Maintained
Maintained
Maintained
Maintained
Maintained
Maintained
Maintained
Maintained
'
M
FC9Y-B1722
SER
S
ANUAL
When
Power
OFF
Maintained
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Maintained
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Maintained
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W

Hide quick links: