Analog Parameter Settings
This section describes the analog parameter settings required to use the analog I/O cartridges.
The analog parameter settings are performed for each channel. In Expansion Modules Configuration, configure the parameter
settings according the application.
For detailed configuration methods, see "Module Configuration Editor" on page 12-1.
Setting Details
The analog parameter settings include the filter, signal type, data type, minimum value, maximum value, data, and status.
(1)
(1) Filter
The analog I/O cartridge's analog input is filtered so it reaches approximately 99% of the analog input in the specified filter.
Even when the analog input varies rapidly, the filtered analog input value can be made to vary smoothly by setting the filter.
When the filter is set to a large value, the tracking of the filtered analog input value becomes slower in regard to the fluctuations
in analog input.
Input filter example
100
90
80
70
60
50
40
30
20
10
0
-20
0
Filter (ms)
0
50 to 50,000
(2)
(3)
Filter: 100 ms
20
40
60
Elapsed time (ms)
The value is not filtered.
The analog input filter can be set in 50 ms increments.
The analog input is filtered so it reaches 99% of the analog input in the specified filter time.
FC6A S
MICROS
ERIES
(4)
Reaches approximately 99% of the analog
input in the set filter (100 ms).