User Program Capacity

This section describes the function to select the user program capacity on the FC6A Series MICROSmart.
Function Description
If the default FC6A Series MICROSmart user program capacity is insufficient, you can secure a larger user program capacity.
However, Online Edit can no longer be used.
CPU Module Type
All-in-One CPU Module
CAN J1939 All-in-One
CPU Module
Plus CPU Module
Programming WindLDR
You can set the user program capacity of the All-in-One CPU module and CAN J1939 All-in-One CPU module.
The Plus CPU module is fixed to 800,000 bytes.
On the Configuration tab, in the Function Area Settings group, click Device Settings.
1.
The Function Area Settings dialog box is displayed.
For Program Capacity Selection, select 72,000 bytes, 384,000 bytes (All-in-One CPU module), or 640,000 bytes (CAN
2.
J1939 All-in-One CPU module).
Click OK.
3.
This concludes configuring the settings.
5-70
Default Capacity
72,000 bytes (9,000 steps)
800,000 bytes (100,000 steps)
FC6A S
MICROS
ERIES
User Program Capacity
When Securing a Larger User Program Capacity
384,000 bytes (48,000 steps)
640,000 bytes (80,000 steps)
U
'
M
FC9Y-B1722
MART
SER
S
ANUAL