Channel Setup - Teledyne LeCroy T3DSO2000A Series User Manual

Digital oscilloscope
Hide thumbs Also See for LeCroy T3DSO2000A Series:
Table of Contents

Advertisement

12.2 Channel Setup

Touch the channel descriptor box, a quick dialog will pop up. Vertical scale and offset
can also be set from this dialog box.
The vertical scale can be adjusted in coarse or fine mode. Use fine mode to scale the
display such that the waveform fills the entire display to achieve the best measurement
accuracy in the vertical direction. The oscilloscope automatically switches to fine mode
when the vertical scale is altered by a touch gesture.
Activating a channel or touching
channel dialog box, displaying more parameters, see next page.
1.800.561.8187
A. Touch the region to set the vertical scale with the
universal knob or virtual keypad
B. ▲ to increase the vertical scale and ▼ to decrease
C. Check to coarsely adjust the vertical scale and
uncheck to enable fine adjustment
D. Touch the region to set the offset with universal
knob or virtual keypad
E. ▲ to increase the offset and ▼ to decrease
F. Set the offset to zero
G. Copy the setting of current channel to another
channel
H. Quickly apply current channel as source of a
specified operation
I. Disable the channel
J. Open the dialog box on the right side
in the quick dialog of the channel recalls the
www.
.com
information@itm.com