Adjust display orientation (optional)

To improve field access to wiring or to better view the optional LCD display:
Prerequisites
Note
In high vibration applications, the transmitter housing must be fully engaged into the
sensor module to meet the vibration test specifications. This is achieved by rotating the
transmitter housing clockwise to thread limit.
Procedure
1. Loosen the set screw until the transmitter housing can rotate smoothly.
2. First, rotate the housing clockwise to the desired location. If the desired location
3. Re-tighten the set screw.
Rosemount 5408 and 5408:SIS Level Transmitters
cannot be achieved due to thread limit, rotate the housing counterclockwise to the
desired location (up to 360° from thread limit).
Figure 3-21: Rotate the Transmitter Housing
Torque 30 in-lb (3 N-m)