Table 7-2: Configuration Error Details
Host diagnostic message
Function Not Supported
Antenna Type Configuration
Error
Factory Calibration Error
Analog Out Span
Configuration Error
Analog Out Calibration Error
SIS Multidrop Error
Engineering Unit
Configuration Error
Burst Mode Configuration
Error
Rosemount 5408 and 5408:SIS Level Transmitters
(continued)
Description
Functionality in the device is enabled, but
not supported by this device.
Additional features may be enabled by
purchasing an upgrade of the device.
The configured Antenna Type is not
supported by the device.
The factory calibration in the device is
missing.
The span for the configured analog out
range is too small.
Analog output calibration failed.
HART multidrop mode is not supported for
safety (SIS) devices. Only 4-20 mA output is
supported for safety devices.
One of the configured engineering units is
not supported by the device.
The burst mode configuration is incorrect.
Service and troubleshooting
Recommended actions
1. Check that selections for variables
(e.g. Primary Variable) are supported
by this device.
2. Turn off functionality not supported
by this device.
3. Consider purchasing an upgrade of
the device to access additional
variables and functionality.
4. If condition persists, restore default
settings and reconfigure device.
1. Check configuration of Antenna Type.
2. Make sure the configured antenna
type matches the physical antenna for
the device.
Replace the device.
Increase analog out span by adjusting
Upper or Lower Range Value.
1. Try calibrating the analog output
again.
2. If the condition persists, replace the
device.
1. Disable multidrop mode.
2. Change Operational Mode to Control/
Monitoring if device is not intended to
be used as safety device.
3. If the condition persists, restore
default settings and reconfigure
device.
1. Check unit configuration.
2. If condition persists, restore default
settings and reconfigure device.
1. Check configuration of burst mode.
2. If condition persists, restore default
settings and reconfigure device.