Figure 3-7: Mounting of the Process Seal Antenna
Table 3-6: Nozzle Requirements for Process Seal Antenna
Antenna size
2-in. (DN50)
3-in. (DN80)
4-in. (DN100)
(1)
The antennas are sized to fit within schedule 120 or lower schedules.
(2)
For hygienic applications, the nozzle height (H) must not exceed two times the nozzle diameter
(D) to ensure cleanability. Maximum nozzle height is 5 in. (127 mm).
Nozzle requirements for parabolic antenna
See
Table 3-7
Figure 3-8: Mounting of the Parabolic Antenna
H
A. Nozzle mounting
B. Flange mounting in manhole cover
28
Minimum nozzle diameter (D)
1.77 in. (45 mm)
2.76 in. (70 mm)
2.76 in. (70 mm)
for nozzle height recommendations at different inclination angle.
A
H
D
(1)
Recommended maximum nozzle height
(2)
(H)
4 ft. (1.2 m)
4 ft. (1.2 m)
4 ft. (1.2 m)
B
Ø 8 in. (200 mm)