Emerson Rosemount 5408 Reference Manual page 38

Level transmitters, non-contacting radar with hart protocol
Hide thumbs Also See for Rosemount 5408:
Table of Contents

Advertisement

Mechanical installation
February 2020
Postrequisites
Align the transmitter head (see
3.5.4
Flanged version with air purge ring (option code PC1)
Prerequisites
If applicable, assemble the segmented cone antenna (see
antenna).
Procedure
1. Place a suitable gasket on the tank flange.
2. Place the purge ring over the gasket.
3. Place a suitable gasket over the purge ring.
4. Lower transmitter with antenna and flange into the nozzle.
38
Note
A minimum gasket thickness of 0.125 in. (3.2 mm) is required for flanges with
protective plate design.
A. Antenna with air purge holes
Align transmitter
head).
Reference Manual
00809-0100-4408
Assemble the segmented cone
Reference Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rosemount 5408:sis

Table of Contents