Quick Start Guide
00825-0600-4026, Rev BA
December 2016
Rosemount
5400 Level Transmitter
Mounting Instructions for Parabolic Antenna

Advertisement

loading
Need help?

Need help?

Do you have a question about the Rosemount 5400 and is the answer not in the manual?

Questions and answers

Summary of Contents for Emerson Rosemount 5400

  • Page 1 Quick Start Guide 00825-0600-4026, Rev BA December 2016 ™ Rosemount 5400 Level Transmitter Mounting Instructions for Parabolic Antenna...
  • Page 2: Table Of Contents

    Avoid contact with the leads and terminals. High voltage that may be present on leads can cause electrical shock.  Make sure the main power to the Rosemount 5400 Level Transmitter is off and the lines to any other external power source are disconnected or not powered while wiring the transmitter. ...
  • Page 3: Parabolic Antenna Overview

    Quick Start Guide December 2016 Parabolic antenna overview Flanged version page 4 Threaded version page 5 Welded version page 9...
  • Page 4: Mount The Flanged Version

    December 2016 Quick Start Guide Mount the flanged version Step 1: Mount the device on tank Tighten the bolts and nuts with sufficient torque for the flange and gasket choice. Gasket Step 2: Adjust the inclination of the antenna (see page 15) Step 3: Connect the air purging (see page 19)
  • Page 5: Mount The Threaded Version

    Quick Start Guide December 2016 Mount the threaded version Figure 1. Componen Antenna Lock nut G 3½" (optional with order) Purge plug kit (optional with order) P/N 05400-1200-0002 P/N 05400-1200-0001 Antenna adapter with ball joint Threaded sleeve O-ring M20 adapter...
  • Page 6 December 2016 Quick Start Guide Step 1: Remove the lock nut (if applicable) Step 2: Mount the O-ring Step 3: Mount the antenna adapter on flange/manhole cover Ensure the antenna adapter fits tightly to the flange/manhole cover. Ø 3.98 ± 0.02 in. (Ø...
  • Page 7: Quick Start Guide December

    Quick Start Guide December 2016 Step 4: Remove the M20 adapter Visually inspect the O-rings for damage and dirt. O-rings Step 5: Carefully insert the antenna Step 6: Secure the antenna Torque 180 in-lb (20 Nm) 27 mm...
  • Page 8 December 2016 Quick Start Guide Step 7: Tighten the set screw Torque 5 in-lb (0.5 Nm) H2 mm Step 8: Mount the antenna assembly on tank Tighten the bolts and nuts with sufficient torque for the flange and gasket choice. Gasket Step 9: Adjust the inclination of the antenna (see page 15) Step 10: Connect the air purging (see page 19)
  • Page 9: Mount The Welded Version

    Quick Start Guide December 2016 Mount the welded version Figure 2. Component Antenna Weld protection plate Clamp flange Purge plug kit (optional with order) Flange ball Washer P/N 05400-1200-0001 Weld protection bar M8 screw Threaded sleeve O-ring M20 adapter Ball joint...
  • Page 10 December 2016 Quick Start Guide Step 1: Mount the protection plates to flange/manhole cover These plates protects the internal surfaces of the flange ball from dust and sparks during welding. Ø 3.94 ± 0.02 in. (Ø 100 ± 0.5 mm) Max.
  • Page 11 Quick Start Guide December 2016 Step 2: Weld the flange ball Step 3: Remove the protection plates Visually inspect the internal surfaces of the flange ball for damage and dirt. Step 4: Mount the O-ring...
  • Page 12 December 2016 Quick Start Guide Step 5: Mount the ball joint Insert the ball joint, place the clamp flange with the “7 Nm” marking side up, and then gradually tighten the M8 screws. Torque 65 in-lb (7 Nm) H6 mm Step 6: Remove the M20 adapter Visually inspect the O-rings for damage and dirt.
  • Page 13 Quick Start Guide December 2016 Step 7: Carefully insert the antenna Step 8: Secure the antenna Torque 180 in-lb (20 Nm) 27 mm...
  • Page 14 December 2016 Quick Start Guide Step 9: Tighten the set screw Torque 5 in-lb (0.5 Nm) H2 mm Step 10: Mount the antenna assembly on tank Tighten the bolts and nuts with sufficient torque for the flange and gasket choice. Gasket Step 11: Adjust the inclination of the antenna (see page 15) Step 12: Connect the air purging (see page 19)
  • Page 15: Adjust The Inclination Of The Antenna

    Quick Start Guide December 2016 Adjust the inclination of the antenna Orientation General best practice is to initially align the parabolic antenna vertically to  the ground. 90° If the surface echo is weak, a small inclination of the antenna toward the ...
  • Page 16 December 2016 Quick Start Guide Procedure Step 1: Remove the transmitter head (if applicable) 60 mm Step 2: Loosen the M8 screws until the antenna can tilt smoothly H6 mm Contents may be under pressure Do not loosen the M8 screws while in operation. Attempting to do so may release pressurized gases, resulting in serious injury or death.
  • Page 17 Quick Start Guide December 2016 Step 4: Adjust the inclination of the antenna Step 5: Gradually tighten the M8 screws Torque 65 in-lb (7 Nm) H6 mm...
  • Page 18 December 2016 Quick Start Guide Step 6: Remove the circular level Step 7: Mount the transmitter head Torque 355 in-lb (40 Nm) 60 mm 36 mm...
  • Page 19: Connect The Air Purging

    Quick Start Guide December 2016 Connect the air purging If air purging is not used, plug and seal the entry with the air plug kit (optional with order) or a suitable blanking plug. Air purging? Use thread sealant or Torque 180 in-lb (20 Nm) gasket according to 17 mm your site procedures.
  • Page 20 Emerson FZE P.O. Box 17033 and Conditions of Sale page. Jebel Ali Free Zone - South 2 The Emerson logo is a trademark and service mark of Emerson Dubai, United Arab Emirates Electric Co. +971 4 8118100 Rosemount and Rosemount logotype are trademarks of Emerson.