Emerson Rosemount 5408 Reference Manual page 25

Level transmitters, non-contacting radar with hart protocol
Hide thumbs Also See for Rosemount 5408:
Table of Contents

Advertisement

Reference Manual
00809-0100-4408
Figure 3-4: Inclination
A. Cone antenna/process seal antenna
B. Parabolic antenna
3.3.5
Non-metallic tanks
The walls in non-metallic tanks can be invisible to the radar signal, so nearby objects
outside the tank may cause disturbing radar echoes. Wherever possible, the transmitter
should be positioned so that objects close to the tank are kept outside the signal beam.
3.3.6
Beam width and beam angle
The transmitter should be mounted with as few internal structures as possible within the
signal beam. Refer to
distances.
Rosemount 5408 and 5408:SIS Level Transmitters
A
Max. 3°
90°
Table 3-3
for beam angle and
B
Max. 1.5°
90°
Table 3-4
for beam width at different
Mechanical installation
February 2020
25