Specifications and reference data
February 2020
Figure A-9: Air Purging for Parabolic Antenna
An air purge connection is also available for cone antennas with flanged connection by
selecting option code PC1. This option consists of an antenna with purge holes and a
separate air purge ring (see
Figure A-10: Air Purging for Cone Antenna
Incoming air supply specification
Maximum pressure: 190 psi (13 bar)
Recommended pressure: 100 to 115 psi (7 to 8 bar)
Inlet/outlet connection: BSPP (G) ⅜-in.
Air consumption: 252 gal/min at 65 psi (955 l/min at 4.5 bar)