Table B-5: For Divisions:
Temperature class /
Maximum surface
temperature
Division Gas groups:
T2
T3
T4
T5
T6
Division Dust groups:
T3
T4
T5
T6
Table B-6: For Zones:
Temperature class /
Maximum surface
temperature
Zone Gas groups:
T2
T3
T4
T5
T6
Zone Dust groups:
T250°C
T200°C
T135°C
T100°C
T85°C
B.10.2
I6 Intrinsically Safe and Non-Incendive Systems
Certificate
Standards
Rosemount 5408 and 5408:SIS Level Transmitters
Ambient temperature range
-40 °C ≤ Ta ≤ 70 °C
-40 °C ≤ Ta ≤ 70 °C
-40 °C ≤ Ta ≤ 70 °C
-40 °C ≤ Ta ≤ 70 °C
-40 °C ≤ Ta ≤ 70 °C
-50 °C ≤ Ta ≤ 70 °C
-50 °C ≤ Ta ≤ 70 °C
-50 °C ≤ Ta ≤ 70 °C
-50 °C ≤ Ta ≤ 70 °C
Ambient temperature range
-50 °C ≤ Ta ≤ 70 °C
-50 °C ≤ Ta ≤ 70 °C
-50 °C ≤ Ta ≤ 70 °C
-50 °C ≤ Ta ≤ 70 °C
-50 °C ≤ Ta ≤ 70 °C
-60 °C ≤ Ta ≤ 70 °C
-60 °C ≤ Ta ≤ 70 °C
-60 °C ≤ Ta ≤ 70 °C
-60 °C ≤ Ta ≤ 70 °C
-60 °C ≤ Ta ≤ 70 °C
FM-C FM16CA0011X
C22.2 NO. 0.4-17:2017, C22.2 NO. 0.5-16:2016, C22.2 No. 25-17:2017,
C22.2 No.94-M91:1991 (R:2011), C22.2 No. 213-16:2016, C22.2 No.
Product certifications
February 2020
Process temperature range
-40 °C to 250 °C
-40 °C to 195 °C
-40 °C to 130 °C
-40 °C to 95 °C
-40 °C to 80 °C
-50 °C to 160 °C
-50 °C to 130 °C
-50 °C to 95 °C
-50 °C to 80 °C
Process temperature range
-50 °C to 250 °C
-50 °C to 195 °C
-50 °C to 130 °C
-50 °C to 95 °C
-50 °C to 80 °C
-60 °C to 250 °C
-60 °C to 195 °C
-60 °C to 130 °C
-60 °C to 95 °C
-60 °C to 80 °C