Emerson Rosemount 5408 Reference Manual page 224

Level transmitters, non-contacting radar with hart protocol
Hide thumbs Also See for Rosemount 5408:
Table of Contents

Advertisement

Product certifications
February 2020
Temperature class /
Maximum surface
temperature
Gas groups:
T2
T3
T4
Dust groups:
T250°C
T200°C
T135°C
T100°C
T85°C
B.11.3
N1 ATEX Type N: Non-Sparking
Certificate
Standards
Markings
Specific Conditions of Use (X):
1. The Model 5408 Level Transmitter will not pass the 500Vrms dielectric strength test
2. Plastic wire-on tag, Plastic part of Process Seal Antenna and Non-standard paint
3. Cable entries must be used which maintain the ingress protection of the enclosure
4. The applicable temperature class, ambient temperature range and process
224
Ambient temperature range
-60 °C ≤ Ta ≤ 70 °C
-60 °C ≤ Ta ≤ 70 °C
-60 °C ≤ Ta ≤ 70 °C
-60 °C ≤ Ta ≤ 70 °C
-60 °C ≤ Ta ≤ 70 °C
-60 °C ≤ Ta ≤ 70 °C
-60 °C ≤ Ta ≤ 70 °C
-60 °C ≤ Ta ≤ 70 °C
FM15ATEX0056X
EN IEC 60079-0:2018, EN 60079-15:2010, EN 60529:1991+A1:2000
+A2:2013
II 3G Ex nA IIC T4...T2 Gc, IP65
(-34 °C ≤ Ta ≤ +70 °C)
V ≤ 42.4V, I ≤ 23 mA
between the circuits and the earth ground. This must be taken into account during
installation.
options (paint options other than Rosemount Blue) may cause risk from
Electrostatic discharge. Avoid installation that could cause electrostatic build-up,
and only clean with a damp cloth.
to at least IP65. To maintain the ingress protection ratings, Covers and Sensor
Module to be fully tightened and PTFE tape or pipe dope is required for cable entries
and blanking plugs. See Instruction Manual on application requirements.
temperature range of the equipment is as follows:
Reference Manual
00809-0100-4408
Process temperature range
-60 °C to 250 °C
-60 °C to 195 °C
-60 °C to 130 °C
-60 °C to 250 °C
-60 °C to 195 °C
-60 °C to 130 °C
-60 °C to 95 °C
-60 °C to 80 °C
Reference Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rosemount 5408:sis

Table of Contents