NEC 78K0/KD1 Series User Manual page 243

8-bit single-chip microcontrollers
Table of Contents

Advertisement

(8) Interrupt request flag (ADIF)
The interrupt request flag (ADIF) is not cleared even if the analog input channel specification register (ADS) is
changed.
Therefore, if an analog input pin is changed during A/D conversion, the A/D conversion result and ADIF for the
pre-change analog input may be set just before the ADS rewrite. Caution is therefore required since, at this time,
when ADIF is read immediately after the ADS rewrite, ADIF is set despite the fact A/D conversion for the post-
change analog input has not ended.
When A/D conversion is stopped and then resumed, clear ADIF before the A/D conversion operation is resumed.
Figure 12-22. Timing of A/D Conversion End Interrupt Request Generation
ADS rewrite
(start of ANIn conversion)
A/D conversion
ADCR
INTAD
Remarks 1. n = 0 to 7
2. m = 0 to 7
(9) Conversion results just after A/D conversion start
The first A/D conversion value immediately after A/D conversion starts may not fall within the rating. Take
measures such as polling the A/D conversion end interrupt request (INTAD) and removing the first conversion
result.
(10) A/D conversion result register (ADCR) read operation
When a write operation is performed to the A/D converter mode register (ADM) and analog input channel
specification register (ADS), the contents of ADCR may become undefined. Read the conversion result following
conversion completion before writing to ADM and ADS. Using timing other than the above may cause an
incorrect conversion result to be read.
Do not read ADCR when the CPU is operating on the subsystem clock and oscillation of the X1 input clock is
stopped.
CHAPTER 12 A/D CONVERTER
ADS rewrite
(start of ANIm conversion)
ANIn
ANIn
ANIn
Preliminary User's Manual U16315EJ1V0UD
ADIF is set but ANIm conversion
has not ended.
ANIm
ANIm
ANIn
ANIm
ANIm
243

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents