Install The Optional Bearingless Rack Slide Set - Comtech EF Data MBT-5000A Installation And Operation Manual

L-band up/down converter system
Table of Contents

Advertisement

To install either kit, do these steps:
Step
Task
Use the #10 flat washers, #10 split washers, and #10 hex nuts to secure the #10 shoulder screws to the unit
1
chassis through the rear right and left side mounting slots.
Use the #10 rack bracket bolts to install the rear support brackets onto the rack enclosure threaded rear
2
mounting rails.
Mount the unit into the rack enclosure. Ensure that the shoulders of the #10 shoulder screws properly engage
3
into the rear support bracket slots.
2.2.2

Install the Optional Bearingless Rack Slide Set

If you wish to mount the converter on slides, you may install an optional bearingless rack slide set
(Figure 2-4) into the rack cabinet and onto the sides of the MBT-5000A. Use the hardware
provided with the slide set that is appropriate for your specific installation:
CEFD Part Number
FP/SL0006
FP/SL0007
FP/SL0008
To install any of these optional bearingless rack slide sets, do these steps:
Step
Task
1
Use the provided mounting hardware to install one slide onto each side of the MBT-5000A chassis,.
2
Use the provided mounting hardware to install the slide rail components into each side of the rack cabinet.
Mount the unit into the equipment rack – make sure that the slides properly engage the cabinet-mounted
3
slide rails.
Slide the converter into the rack cabinet until the front panel's back surfaces abut the rack cabinet's front
4
mounting rails.
Use four user-provided screws to secure the converter to the rack cabinet front mounting rails (see
5
Figure 2-2).
Installation
Bearingless Rack Slide Set – 26"
Bearingless Rack Slide Set – 24"
Bearingless Rack Slide Set – 22"
MBT-5000A L-Band Up/Down Converter System
Description
2–5
Revision 1
MN-MBT-5000A