Sign In
Upload
Manuals
Brands
Comtech EF Data Manuals
Media Converter
MBT-5000A
Comtech EF Data MBT-5000A Manuals
Manuals and User Guides for Comtech EF Data MBT-5000A. We have
1
Comtech EF Data MBT-5000A manual available for free PDF download: Installation And Operation Manual
Comtech EF Data MBT-5000A Installation And Operation Manual (153 pages)
L-Band Up/Down Converter System
Brand:
Comtech EF Data
| Category:
Media Converter
| Size: 3 MB
Table of Contents
Table of Contents
3
Preface
11
Conventions and References
11
Patents and Trademarks
11
Warnings, Cautions, and Notes
11
Examples of Multi-Hazard Notices
12
Recommended Standard Designations
12
Safety and Compliance
12
Electrical Safety and Compliance
12
Electrical Installation
12
Operating Environment
13
European Union Radio Equipment and Telecommunications Terminal Equipment (R&TTE) Directive (1999/5/EC) and en 301 489-1
13
European Union Electromagnetic Compatibility (EMC) Directive (2004/108/EC)
13
European Union Low Voltage Directive (LVD) (2006/95/EC)
14
European Union Rohs Directive (2002/95/EC)
14
European Union Telecommunications Terminal Equipment Directive (91/263/EEC)
14
CE Mark
14
Product Support
14
Comtech EF Data Headquarters
15
Warranty Policy
15
Limitations of Warranty
15
Exclusive Remedies
16
Chapter 1. Introduction
17
Overview
17
Functional Description
17
Figure 1-1. MBT-5000A L-Band Up/Down Converter
17
Figure 1-2. MBT-5000A Operational Schematics
18
Features
19
Block Upconverter (BUC-5000A)
19
Block Downcoverter (BDC-5000A)
20
Summary of Specifications
21
Physical & Environmental
21
Prime Power
21
Monitor & Control
21
Reference
22
BUC-5000A Block Upconverters
22
BDC-5000A Block Downconverters
24
Dimensional Envelope
25
Figure 1-3. MBT-5000A Dimensional Envelope
25
Chapter 2. Installation
26
Unpack and Inspect the Shipment
26
Figure 2-1. MBT-5000A Packing/Shipping Diagram
26
Install the Unit into a Rack Enclosure
27
Figure 2-2. Unit Rack Enclosure Installation
28
Optional Rear-Mounting Support Brackets Kit Installation
29
Figure 2-3. Optional Rear-Mounting Support Brackets Kit Installation
29
Install the Optional Bearingless Rack Slide Set
30
Figure 2-4. Optional Bearingless Rack Slide Installation (FP/SL000X)
31
Chapter 3. Rear Panel Connections
32
Cabling Connection Types
32
Coaxial Cable Connections
32
Figure 3-1. Coaxial Connector Examples
32
Type 'BNC
33
Type 'N
33
Type 'TNC
33
Type 'F
34
Type 'SMA' (Subminiature Version 'A')
34
D-Subminiature Cable Connections
34
Figure 3-2. D-Subminiature Connector Examples
34
RJ-45, RJ-48 Cable Connections
35
MBT-5000A Cabling Connections
36
Table 3-1. MBT-5000A Connectors
36
Figure 3-3. MBT-5000A Cabling Connections
36
IF Connector Group
37
J4 | if OUT/IN' (Side B) Connector (Type 'N' Female)
37
J5 | RF IN/OUT' (Side B) Connector (Type 'N' Female)
37
J6 | if OUT/IN' (Side A) Connector (Type 'N' Female)
37
J7 | RF IN/OUT' (Side A) Connector (Type 'N' Female)
37
Optional Redundancy Groups
38
Optional 'IF' Connectors (Type 'SMA' Female)
38
Optional 'RF' Connectors (Type 'SMA' Female)
38
Utility Connector Group
38
J2 | EXT REF IN' - External Reference Input Connector (BNC-F)
38
J8 | EXT REF OUT' - External Reference Output Connector (BNC-F)
38
J9 | 10/100 ETHERNET' 10/100 Baset M&C Port (RJ-45)
39
Table 3-2. 'J9 | 10/100 ETHERNET' Connector Pinout
39
P1 | RELAY' Summary Fault Output Connector (DB-9F)
40
Table 3-3. 'P1 | RELAY' Connector Pinout
40
J1 | COM 1' EIA-485/232 Interface Connector (DB-9F)
41
Table 3-4. 'J1 | COM1' 2-Wire EIA-485 Interface Connector Pinout
41
MBT-5000A Ground and Power Connections
43
Chassis Ground Interface
43
Figure 3-4. MBT-5000A Chassis - Common Ground Interface
43
Alternating Current (AC) Power Interfaces
44
Standard 90-260V Alternating Current (AC) Power Interface
44
Figure 3-5. MBT-5000A Standard AC Power Interface
44
Figure 3-6. MBT-5000A AC Power
45
Standard 90-260V AC Operation - Apply Power
45
Standard 90-260V AC Operation - Replace the Fuses
46
Optional Dual Entry Module Alternating Current (AC) Power Interface (Redundancy Units Only)
46
Figure 3-7. MBT-5000A AC Fuse Replacement
46
Figure 3-8. MBT-5000A Optional Dual Entry Module AC Power Interface
46
DC Power Interfaces
47
Optional -48V Direct Current (DC) Power Interface
47
Figure 3-9. MBT-5000A Optional DC Power Interface
47
Figure 3-10. MBT-5000A DC Power
48
Optional -48V DC Operation - Apply Power
48
Figure 3-11. MBT-5000A DC Fuse Replacement
49
Optional -48V DC Operation - Replace the Fuse
49
Chapter 4. Upgrading Firmware
50
Overview
50
About Firmware Files Naming, Versions, and Formats
50
Getting Started: Prepare for the Firmware Download
52
Download and Extract the Firmware Update
56
Perform the Ethernet FTP Upload Procedure
58
Chapter 5 . Front and Rear Panel Operation
60
Overview
60
Figure 5-1. MBT-5000A Front and Rear Panel Views (Redundant Unit Shown)
60
Switch Power on (Rear Panel)
62
LED Indicators
62
Keypad
63
Vacuum Fluorescent Display (VFD)
63
Opening Screen
64
Screen Saver
64
Front Panel Operation
65
Figure 5-2. MBT-5000A Front Panel Menu Tree (Firmware Ver. 1.1.1)
65
SELECT: (Main) Menu
66
SELECT: Config (Configuration) Menu Branches
67
CONFIG: Remote (Remote Control) Menus
68
Remote Control: Local
68
Remote Control: Serial
68
Remote Control: Ethernet
69
CONFIG: Conva or Convb (Converter 'A' or Converter 'B') Menus
71
CONFIG: Fltrec (Fault Recovery) Menu
71
Converter X: Mute/Freq
71
CONFIG: Redun (Redundancy) Menus
72
CONFIG: Refadj (Reference Oscillator Adjustment) Menu
72
Converter X: Attenuation
72
Redundancy Mode: Disable/Enable
72
Redundancy Mode: Force
73
SELECT: Monitor Menu Branch
74
Monitor: Faults
74
Monitor: Mask
75
Out-Of-Range Power Supply Masking Using the PS Submenu
75
Monitor: Event-Log (Stored Events)
76
Stored Events: View
76
Monitor: LPT (Low Power Threshold)
77
Stored Event: Clear-All
77
SELECT: Info (Information) Menu Branch
78
INFO: Remote (Remote Control)
78
INFO: Conva (Converter 'A') or Convb (Converter 'B')
79
INFO: MC (Voltage Generated on the M&C)
79
INFO: PS1 or PS1 (Power Supply '1' or Power Supply '2')
79
INFO: Ref (Reference Oscillator)
79
INFO: EOD (Equipment Odometer)
80
SELECT: Utility Menu Branch
81
UTILITY: CID (Circuit ID)
81
UTILITY: Date/Time (Set Real-Time Clock)
81
Firmware Images: Info
82
Firmware Images: Select
82
UTILITY: Display (VFD Display Brightness)
82
UTILITY: Firmware
82
LNA: Convx (Conva or Convb)
83
Utility: Lna
83
SELECT: Test Menu Branch
85
Chapter 6. Ethernet-Based Remote Product Management
86
Overview
86
Ethernet Management Interface Protocols
87
SNMP Interface
88
Management Information Base (MIB) Files
88
SNMP Community Strings
89
SNMP Traps
89
Telnet Interface
90
Telnet Operation Via Hyperterminal
91
HTTP (Web Server) Interface
92
Enable the Web Server Interface
92
User Login
93
Web Server Interface - Operational Features
94
Navigation
94
Page Sections
94
Action Buttons
94
Drop-Down Lists
94
Text or Data Entry
95
Web Server Interface - Menu Tree
95
Web Server Interface
96
Home
96
6.5.5.1.1 Home | Home
96
Figure 6-1. Home | Home Page
96
6.5.5.1.2 Home | Contact
97
Figure 6-2. Home | Contact Page
97
6.5.5.1.3 Home | Support
98
Figure 6-3. Home | Support Page
98
Admin
99
6.5.5.2.1 Admin | Access
99
6.5.5.2.2 Admin | SNMP
101
Config
102
6.5.5.3.1 Config | MBT
102
6.5.5.3.2 Config | Utility
105
6.5.5.3.3 Config | Redundancy
107
Status
108
6.5.5.4.1 Status | Events
108
6.5.5.4.2 Status | Status
110
Critical Status
112
Chapter 7. Serial-Based Remote Product Management
114
Overview
114
Remote Commands and Queries Overview
116
Basic Protocol
116
Packet Structure
117
Start of Packet
118
Target Address
118
Address Delimiter
118
Instruction Code
119
Instruction Code Qualifier
119
Optional Message Arguments
120
End of Packet
121
Remote Commands and Queries
122
MBT-5000A Base Unit Remote Commands and Queries
124
Block Converter (BUC / BDC) Remote Commands and Queries
135
Appendix A. Buc-5000X/Bdc-5000X Module Removal/Installation
140
Overview
140
Figure A-1. BUC-5000X/Bdc-5000X Module
141
Module Removal Procedure
142
Module Installation Procedure
145
Appendix B. Mbt-5000A Redundancy Operation
148
Overview
148
Configuration
148
Figure B-1. MBT-5000A Redundancy - Functional Schematics
149
Figure B-2. MBT-5000A Redundancy Cabling Requirements
150
Advertisement
Advertisement
Related Products
Comtech EF Data MBT-5003
Comtech EF Data MBT-5000
Comtech EF Data MN/LBC4000.IOM
Comtech EF Data MR-S2
Comtech EF Data MBT-4000
Comtech EF Data MBT-4000B
Comtech EF Data MetaCarrier MCDD-100
Comtech EF Data MN/CDM500.IOM
Comtech EF Data CD-MNLBC4000
Comtech EF Data CIC-50
Comtech EF Data Categories
Modem
Switch
Amplifier
Network Router
Media Converter
More Comtech EF Data Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL