Reference; Buc-5000A Block Upconverters - Comtech EF Data MBT-5000A Installation And Operation Manual

L-band up/down converter system
Table of Contents

Advertisement

1.4.4

Reference

External Input
Internal Output
Internal
1.4.5

BUC-5000A Block Upconverters

Frequency Bands
(by Model)
Input/Output Impedance
Input Return Loss
Output Return Loss
Input Connector
Output Connector
Gain
Mute
User Attenuation Range
Input P1dB With 10 dB Attenuation
Introduction
Thermal Stability
Ageing, per Day
Ageing, per Year
Model
BUC-5000AC
BUC-5000AX
BUC-5000AKu
BUC-5000AKa1
BUC-5000AKa2
BUC-5000AKa3
BUC-5000AKaM
50 Ω
15 dB minimum
15 dB minimum
Type 'N' Female (Type 'SMA' for Redundancy option)
Type 'N' Female (Type 'SMA' for Redundancy option)
2.92 mm for Ka-Band
35 dB nominal at 0 dB Atten., ±2.0 dB
Constant Temp – ±0.25dB
Full Band
-32° to +60° C – ±1.00 dB
Per 40 MHz Slope
.03 dB/MHz maximum
-80 dBm, Max.
0 to 30 dB, in 0.25 dB steps
≥ -12 dBm
MBT-5000A L-Band Up/Down Converter System
5 or 10 MHz, 0 ±5 dBm
BNC Female, 50 Ω, Return Loss 15 dB
5 or 10 MHz, +5.0 dBm, Min
BNC Female, 50 Ω
±1x10E-08
±3x10E-10
±3x10E-08
RF Output
5850-6650 MHz
950-1750 MHz
7900-8400 MHz
950-1450 MHz
13.75-14.50 GHz
950-1700 MHz
27.50-28.50 GHz
1000-2000 MHz
28.30-29.30 GHz
1000-2000 MHz
29.00-30.00 GHz
1000-2000 MHz
30.00-31.00 GHz
1000-2000 MHz
1–6
Revision 1
IF Input
LO
4900 MHz
6950 MHz
12.80 GHz
26.50 GHz
27.30 GHz
28.00 GHz
29.00 GHz
MN-MBT-5000A