Comtech EF Data MBT-5000A Installation And Operation Manual page 70

L-band up/down converter system
Table of Contents

Advertisement

SNMP: Community
SNMP Community: Read
Write Trap
Use the ◄ ► arrows keys to select Read, Write, or Trap, and then press ENTER.
SNMP: Community  Read
Read Community: (◄ ► ▲▼ E)
public
SNMP: Community  Write
Write Community:(◄ ► ▲▼ E)
private
SNMP: Community  Trap
Trap Community:(◄ ► ▲ ▼ E)
comtech
To edit the SNMP Read, Write, or Trap Community strings: First, use the ◄ ►
arrow keys to select a character to edit, and then use the ▲▼arrow keys to edit that
character. Note that only the first 20 characters on the bottom line are available.
All printable ASCII characters are available with the exception of the backslash '/'
(ASCII code 92) and tilde '~' (ASCII code 126).
Press ENTER once you compose the string – the MBT-5000A removes all trailing
spaces from the string upon entry.
SNMP: Traps
SNMP Trap IP Address:
IP1 IP2 Version
Use the ◄ ► arrow keys to select IP1, IP2, or Version, and then press ENTER.
SNMP Trap IP Address: IP1 or IP2
Trap IP #1:
000.000.000.000(◄ ► ▲ ▼ E)
Trap IP #2:
000.000.000.000(◄ ► ▲ ▼ E)
To edit the Trap Destination IP Addresses: First, use the ◄ ► arrow keys to select
the digit to edit, and then use the ▼▲ arrow keys to edit the value of that digit. Press
ENTER when done.
Front Panel Operation
(◄ ► E)
If both Trap IP Addresses are 000.000.000.000, it means Traps are
disabled.
5–11
MBT-5000A L-Band Up/Down Converter System
Revision 1
MN-MBT-5000A