Standard 90-260V Ac Operation - Replace The Fuses; Optional Dual Entry Module Alternating Current (Ac) Power Interface (Redundancy Units Only); Figure 3-7. Mbt-5000A Ac Fuse Replacement; Figure 3-8. Mbt-5000A Optional Dual Entry Module Ac Power Interface - Comtech EF Data MBT-5000A Installation And Operation Manual

L-band up/down converter system
Table of Contents

Advertisement

3.3.2.1.2
Standard 90-260V AC Operation – Replace the Fuses
WARNING! DISCONNECT THE POWER SUPPLY BEFORE PROCEEDING!
CAUTION – FOR CONTINUED OPERATOR SAFETY, ALWAYS REPLACE THE
FUSES WITH THE CORRECT TYPE AND RATING.
The MBT-5000A uses two 20 mm slow-blow fuses – one each for line and neutral connections
(L1, L2 where appropriate). The fuses are located in the rear panel at the International
Electrotechnical Commission (IEC) AC power supply module (Figure 3-7). The fuses are
contained within a fuse holder that is press-fit into the body of the module.
To replace the AC fuses, do these steps:
First, unseat the fuse holder from the IEC power module.
Use the slot to pry the holder outward from the IEC power module.
o
Pull the holder straight out, and then swing the holder away from the module.
o
Then, remove and replace the fuses as needed.
Use T2.0A (2 Amp) fuses for standard operation.
o
Finally, re-seat the fuse holder in the IEC power module.
3.3.2.2
Optional Dual Entry Module Alternating Current (AC) Power
Interface (Redundancy Units Only)

Figure 3-8. MBT-5000A Optional Dual Entry Module AC Power Interface

Rear Panel Connections

Figure 3-7. MBT-5000A AC Fuse Replacement

3–15
MBT-5000A L-Band Up/Down Converter System
Revision 1
MN-MBT-5000A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MBT-5000A and is the answer not in the manual?

Questions and answers

Table of Contents