Ext. Closed Loop - Danfoss VLT AQUA Drive FC 200 Programming Manual

Hide thumbs Also See for VLT AQUA Drive FC 200:
Table of Contents

Advertisement

Parameter Lists

4.1.18 21-** Ext. Closed Loop

Par. No. #
Parameter description
21-0* Ext. CL Autotuning
21-00
Closed Loop Type
21-01
PID Performance
21-02
PID Output Change
21-03
Minimum Feedback Level
21-04
Maximum Feedback Level
21-09
PID Auto Tuning
21-1* Ext. CL 1 Ref./Fb.
21-10
Ext. 1 Ref./Feedback Unit
21-11
Ext. 1 Minimum Reference
21-12
Ext. 1 Maximum Reference
21-13
Ext. 1 Reference Source
21-14
Ext. 1 Feedback Source
21-15
Ext. 1 Setpoint
21-17
Ext. 1 Reference [Unit]
21-18
Ext. 1 Feedback [Unit]
21-19
Ext. 1 Output [%]
21-2* Ext. CL 1 PID
21-20
Ext. 1 Normal/Inverse Control
21-21
Ext. 1 Proportional Gain
21-22
Ext. 1 Integral Time
21-23
Ext. 1 Differentation Time
21-24
Ext. 1 Dif. Gain Limit
21-3* Ext. CL 2 Ref./Fb.
21-30
Ext. 2 Ref./Feedback Unit
21-31
Ext. 2 Minimum Reference
21-32
Ext. 2 Maximum Reference
21-33
Ext. 2 Reference Source
21-34
Ext. 2 Feedback Source
21-35
Ext. 2 Setpoint
21-37
Ext. 2 Reference [Unit]
21-38
Ext. 2 Feedback [Unit]
21-39
Ext. 2 Output [%]
21-4* Ext. CL 2 PID
21-40
Ext. 2 Normal/Inverse Control
21-41
Ext. 2 Proportional Gain
21-42
Ext. 2 Integral Time
21-43
Ext. 2 Differentation Time
21-44
Ext. 2 Dif. Gain Limit
21-5* Ext. CL 3 Ref./Fb.
21-50
Ext. 3 Ref./Feedback Unit
21-51
Ext. 3 Minimum Reference
21-52
Ext. 3 Maximum Reference
21-53
Ext. 3 Reference Source
21-54
Ext. 3 Feedback Source
21-55
Ext. 3 Setpoint
21-57
Ext. 3 Reference [Unit]
21-58
Ext. 3 Feedback [Unit]
21-59
Ext. 3 Output [%]
®
VLT
AQUA Drive Programming Guide
Default value
[0] Auto
[0] Normal
0.10 N/A
-999999.000 N/A
999999.000 N/A
[0] Disabled
[0]
0.000 ExtPID1Unit
100.000 ExtPID1Unit
[0] No function
[0] No function
0.000 ExtPID1Unit
0.000 ExtPID1Unit
0.000 ExtPID1Unit
0 %
[0] Normal
0.50 N/A
20.00 s
0.00 s
5.0 N/A
[0]
0.000 ExtPID2Unit
100.000 ExtPID2Unit
[0] No function
[0] No function
0.000 ExtPID2Unit
0.000 ExtPID2Unit
0.000 ExtPID2Unit
0 %
[0] Normal
0.50 N/A
20.00 s
0.00 s
5.0 N/A
[0]
0.000 ExtPID3Unit
100.000 ExtPID3Unit
[0] No function
[0] No function
0.000 ExtPID3Unit
0.000 ExtPID3Unit
0.000 ExtPID3Unit
0 %
®
MG20O602 - VLT
is a registered Danfoss trademark
4-set-up
Change
Conver-
during
sion
operation
index
2 set-ups
TRUE
-
2 set-ups
TRUE
-
2 set-ups
TRUE
-2
2 set-ups
TRUE
-3
2 set-ups
TRUE
-3
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
0
All set-ups
TRUE
-
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
-1
All set-ups
TRUE
-
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
0
All set-ups
TRUE
-
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
-1
All set-ups
TRUE
-
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
0
Type
Uint8
Uint8
4
4
Uint16
Int32
Int32
Uint8
Uint8
Int32
Int32
Uint8
Uint8
Int32
Int32
Int32
Int32
Uint8
Uint16
Uint32
Uint16
Uint16
Uint8
Int32
Int32
Uint8
Uint8
Int32
Int32
Int32
Int32
Uint8
Uint16
Uint32
Uint16
Uint16
Uint8
Int32
Int32
Uint8
Uint8
Int32
Int32
Int32
Int32
211