Ext. Closed Loop - Danfoss VLT FC 103 Programming Manual

Refrigeration drive
Hide thumbs Also See for VLT FC 103:
Table of Contents

Advertisement

Parameter Lists
Par. No. # Parameter description
20-91
PID Anti Windup
20-93
PID Proportional Gain
20-94
PID Integral Time
20-95
PID Differentiation Time
20-96
PID Diff. Gain Limit
4
4
Table 4.17

4.1.17 21-** Ext. Closed Loop

Par. No. # Parameter description
21-0* Ext. CL Autotuning
21-00
Closed Loop Type
21-01
PID Performance
21-02
PID Output Change
21-03
Minimum Feedback Level
21-04
Maximum Feedback Level
21-09
PID Autotuning
21-1* Ext. CL 1 Ref./Fb.
21-10
Ext. 1 Ref./Feedback Unit
21-11
Ext. 1 Minimum Reference
21-12
Ext. 1 Maximum Reference
21-13
Ext. 1 Reference Source
21-14
Ext. 1 Feedback Source
21-15
Ext. 1 Setpoint
21-17
Ext. 1 Reference [Unit]
21-18
Ext. 1 Feedback [Unit]
21-19
Ext. 1 Output [%]
21-2* Ext. CL 1 PID
21-20
Ext. 1 Normal/Inverse Control
21-21
Ext. 1 Proportional Gain
21-22
Ext. 1 Integral Time
21-23
Ext. 1 Differentation Time
21-24
Ext. 1 Dif. Gain Limit
21-3* Ext. CL 2 Ref./Fb.
21-30
Ext. 2 Ref./Feedback Unit
21-31
Ext. 2 Minimum Reference
21-32
Ext. 2 Maximum Reference
21-33
Ext. 2 Reference Source
21-34
Ext. 2 Feedback Source
21-35
Ext. 2 Setpoint
21-37
Ext. 2 Reference [Unit]
21-38
Ext. 2 Feedback [Unit]
21-39
Ext. 2 Output [%]
21-4* Ext. CL 2 PID
21-40
Ext. 2 Normal/Inverse Control
21-41
Ext. 2 Proportional Gain
21-42
Ext. 2 Integral Time
21-43
Ext. 2 Differentation Time
182
®
VLT
Refrigeration Drive Programming Guide
Default value
4-set-up
[1] On
All set-ups
0.50 N/A
All set-ups
30 s
All set-ups
0 s
All set-ups
5 N/A
All set-ups
Default value
4-set-up
[0] Auto
2 set-ups
[0] Normal
2 set-ups
0.10 N/A
2 set-ups
-999999 N/A
2 set-ups
999999 N/A
2 set-ups
[0] Disabled
All set-ups
[1] %
All set-ups
0 ExtPID1Unit
All set-ups
100 ExtPID1Unit
All set-ups
[0] No function
All set-ups
[0] No function
All set-ups
0 ExtPID1Unit
All set-ups
0 ExtPID1Unit
All set-ups
0 ExtPID1Unit
All set-ups
0 %
All set-ups
[0] Normal
All set-ups
0.01 N/A
All set-ups
10000 s
All set-ups
0 s
All set-ups
5 N/A
All set-ups
[1] %
All set-ups
0 ExtPID2Unit
All set-ups
100 ExtPID2Unit
All set-ups
[0] No function
All set-ups
[0] No function
All set-ups
0 ExtPID2Unit
All set-ups
0 ExtPID2Unit
All set-ups
0 ExtPID2Unit
All set-ups
0 %
All set-ups
[0] Normal
All set-ups
0.01 N/A
All set-ups
10000 s
All set-ups
0 s
All set-ups
®
MG16H102 - VLT
is a registered Danfoss trademark
Change
Conver-
during
sion index
operation
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-1
Change
Conver-
during
sion index
operation
TRUE
-
TRUE
-
TRUE
-2
TRUE
-3
TRUE
-3
TRUE
-
TRUE
-
TRUE
-3
TRUE
-3
TRUE
-
TRUE
-
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
0
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-1
TRUE
-
TRUE
-3
TRUE
-3
TRUE
-
TRUE
-
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
0
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-2
Type
Uint8
Uint16
Uint32
Uint16
Uint16
Type
Uint8
Uint8
Uint16
Int32
Int32
Uint8
Uint8
Int32
Int32
Uint8
Uint8
Int32
Int32
Int32
Int32
Uint8
Uint16
Uint32
Uint16
Uint16
Uint8
Int32
Int32
Uint8
Uint8
Int32
Int32
Int32
Int32
Uint8
Uint16
Uint32
Uint16