Parameter Lists
4.1.2 0-** Operation/Display
Par. No.
Parameter description
#
0-0* Basic Settings
0-01
Language
0-02
Motor Speed Unit
0-03
Regional Settings
0-04
Operating State at Power-up
0-05
Local Mode Unit
0-1* Set-up Operations
0-10
Active Set-up
0-11
Programming Set-up
0-12
This Set-up Linked to
0-13
Readout: Linked Set-ups
0-14
Readout: Prog. Set-ups / Channel
0-2* LCP Display
0-20
Display Line 1.1 Small
0-21
Display Line 1.2 Small
0-22
Display Line 1.3 Small
0-23
Display Line 2 Large
0-24
Display Line 3 Large
0-25
My Personal Menu
0-3* LCP Custom Readout
0-30
Custom Readout Unit
0-31
Custom Readout Min Value
0-32
Custom Readout Max Value
0-37
Display Text 1
0-38
Display Text 2
0-39
Display Text 3
0-4* LCP Keypad
0-40
[Hand on] Key on LCP
0-41
[Off] Key on LCP
0-42
[Auto on] Key on LCP
0-43
[Reset] Key on LCP
0-44
[Off/Reset] Key on LCP
0-45
[Drive Bypass] Key on LCP
0-5* Copy/Save
0-50
LCP Copy
0-51
Set-up Copy
0-6* Password
0-60
Main Menu Password
0-61
Access to Main Menu w/o Password
0-65
Personal Menu Password
Access to Personal Menu w/o
0-66
Password
0-67
Bus Password Access
0-7* Clock Settings
0-70
Date and Time
0-71
Date Format
0-72
Time Format
0-74
DST/Summertime
0-76
DST/Summertime Start
®
VLT
AQUA Drive Programming Guide
Default value
[0] English
[0] RPM
[0] International
[0] Resume
[0] As Motor Speed Unit
[1] Set-up 1
[9] Active Set-up
[0] Not linked
0 N/A
0 N/A
1601
1662
1614
1613
1652
ExpressionLimit
[1] %
ExpressionLimit
100.00 CustomReadoutUnit
0 N/A
0 N/A
0 N/A
[1] Enabled
[1] Enabled
[1] Enabled
[1] Enabled
[1] Enabled
[1] Enabled
[0] No copy
[0] No copy
100 N/A
[0] Full access
200 N/A
[0] Full access
0 N/A
ExpressionLimit
[0] YYYY-MM-DD
[0] 24 h
[0] Off
ExpressionLimit
®
MG20O602 - VLT
is a registered Danfoss trademark
4-set-up
Change
Conver-
during
sion index
operation
1 set-up
TRUE
2 set-ups
FALSE
2 set-ups
FALSE
All set-ups
TRUE
2 set-ups
FALSE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
Type
-
Uint8
-
Uint8
4
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint16
0
Int32
-
Uint16
-
Uint16
-
Uint16
-
Uint16
-
Uint16
0
Uint16
-
Uint8
-2
Int32
-2
Int32
0
VisStr[25]
0
VisStr[25]
0
VisStr[25]
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Int16
-
Uint8
0
Uint16
-
Uint8
0
Uint16
0
TimeOfDay
-
Uint8
-
Uint8
-
Uint8
0
TimeOfDay
189
4