Fc Closed Loop - Danfoss VLT AQUA Drive FC 200 Programming Manual

Hide thumbs Also See for VLT AQUA Drive FC 200:
Table of Contents

Advertisement

Parameter Lists

4.1.17 20-** FC Closed Loop

Par. No. #
20-0* Feedback
20-00
20-01
4
4
20-02
20-03
20-04
20-05
20-06
20-07
20-08
20-12
20-2* Feedback/Setpoint
20-20
20-21
20-22
20-23
20-7* PID Autotuning
20-70
20-71
20-72
20-73
20-74
20-79
20-8* PID Basic Settings
20-81
20-82
20-83
20-84
20-9* PID Controller
20-91
20-93
20-94
20-95
20-96
Table 4.20
210
Parameter description
Feedback 1 Source
Feedback 1 Conversion
Feedback 1 Source Unit
Feedback 2 Source
Feedback 2 Conversion
Feedback 2 Source Unit
Feedback 3 Source
Feedback 3 Conversion
Feedback 3 Source Unit
Reference/Feedback Unit
Feedback Function
Setpoint 1
Setpoint 2
Setpoint 3
Closed Loop Type
PID Performance
PID Output Change
Minimum Feedback Level
Maximum Feedback Level
PID Autotuning
PID Normal/ Inverse Control
PID Start Speed [RPM]
PID Start Speed [Hz]
On Reference Bandwidth
PID Anti Windup
PID Proportional Gain
PID Integral Time
PID Differentiation Time
PID Diff. Gain Limit
MG20O602 - VLT
®
VLT
AQUA Drive Programming Guide
Default value
[2] Analog input 54
[0] Linear
null
[0] No function
[0] Linear
null
[0] No function
[0] Linear
null
null
[4] Maximum
0.000 ProcessCtrlUnit
0.000 ProcessCtrlUnit
0.000 ProcessCtrlUnit
[0] Auto
[0] Normal
0.10 N/A
-999999.000 ProcessCtrlUnit
999999.000 ProcessCtrlUnit
[0] Disabled
[0] Normal
ExpressionLimit
ExpressionLimit
5 %
[1] On
2.00 N/A
8.00 s
0.00 s
5.0 N/A
®
is a registered Danfoss trademark
4-set-up
Change
Conver-
during
sion
operation
index
All set-ups
TRUE
-
All set-ups
FALSE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
FALSE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
FALSE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
-3
2 set-ups
TRUE
-
2 set-ups
TRUE
-
2 set-ups
TRUE
-2
2 set-ups
TRUE
-3
2 set-ups
TRUE
-3
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
67
All set-ups
TRUE
-1
All set-ups
TRUE
0
All set-ups
TRUE
-
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
-1
Type
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Int32
Int32
Int32
Uint8
Uint8
Uint16
Int32
Int32
Uint8
Uint8
Uint16
Uint16
Uint8
Uint8
Uint16
Uint32
Uint16
Uint16

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT AQUA Drive FC 200 and is the answer not in the manual?

Questions and answers

Table of Contents