Coupling Kit
PL6.1.99
WARNING:
The Fuser is very hot. Take added care when handling the fuser to avoid being burned.
1.
Remove the Transfer Belt Assembly. (page 4-38)
2.
Remove the Right Cover Assembly. (page 4-131)
Note:
When performing the following step, use caution not to drop the Dowel Pin (PL6.1.15).
3.
Remove the Coupling Actuator (PL6.1.4).
4.
Pull out the Dowel Pin.
5.
Remove the Coupling Kit (PL6.1.99).
Xerox Internal Use Only
Service Parts Disassembly
Phaser 6600 and WorkCentre 6605
Service Manual
s6600-163
4-45