Error Troubleshooting
042-325 IOT Motor Failure
Step
Check
Possible causative parts:
• Main Motor [Drive Assembly] (PL3.1.1)
• Drive Harness Assembly (PL18.2.2)
• Top Harness Assembly (PL18.2.5)
• LVPS (PL18.1.34)
• MCU Board (PL18.1.13)
1
Check the Main Motor operation
Execute Digital Output diagnostic test 071-001, and check
the Main Motor rotation.
Does the Main Motor function normally?
2
Check the Main Motor connection
Check the connection between the Main Motor and the
LVPS, and the connection between the Main Motor and the
MCU Board.
Are P/J311, P/J509, P/J171 and P/J17 connected securely?
3
Check the continuity between the Main Motor and the MCU
Board
Is each cable of P/J171<=>P/J17 continuous?
4
Check the continuity between the Main Motor and the LVPS
Is each cable of P/J311<=>P/J509 continuous?
5
Check the power to the Main Motor (+24 VDC)
Close the interlock switch(es), and check if the voltage
between the LVPS ground and the P/J509-1 pin is about
+24 VDC.
2-180
Phaser 6600 and WorkCentre 6605
Service Manual
Yes
No
Replace the MCU
Go to step 2.
Board.
Go to step 3.
Connect P/J311,
P/J509, P/J171,
Go to step 4.
Replace the Drive
Go to step 5.
Replace the Top
Replace the Drive
Replace the LVPS.
Assembly.
Xerox Internal Use Only
and P/J17
securely.
Harness
Assembly.
Harness
Assembly.