General Information

Electrical Properties

Power Source
Two types of power source as follows are available for this printer, which are selected according to the
specifications.
110 M/C: ---voltage: 100-127VAC ±10% (90 ~ 140V), frequency: 50/60Hz ± 3Hz
220 M/C: ---voltage: 220-240VAC ±10% (198 ~ 264V), frequency: 50/60Hz ± 3Hz
Power Consumption
Power consumption in each operation mode at rated voltage input
Operation mode
Power off
Printing
Ready
Sleep
Rush Current
When the power switch is turned on, the inrush current shall be maximum 50Amp (Cold start)/135Amp
(Hot start) at first 2.5msec, and 80Amp (120V/220V/240V) / 85Amp (100V) within 10msec.
1-60
Phaser 6600 and WorkCentre 6605
Service Manual
Phaser 6600
0 W
535 W
65 W
4 W
WorkCentre 6605
0 W
560 W
72 W
6 W